Suppr超能文献

多股弓丝和 CAD/CAM 保持器对牙齿动度的限制:一项体外研究。

Tooth mobility restriction by multistranded and CAD/CAM retainers-an in vitro study.

机构信息

Department of Orthodontics and Dentofacial Orthopaedics, Heidelberg University Hospital, Im Neuenheimer Feld 400, Heidelberg, Germany.

Department of Prosthodontics, Heidelberg University Hospital, University of Heidelberg, Im Neuenheimer Feld 400, Heidelberg, Germany.

出版信息

Eur J Orthod. 2024 Jan 1;46(1). doi: 10.1093/ejo/cjad076.

Abstract

OBJECTIVES

Orthodontic retainers should restrict physiological tooth mobility as little as possible. While this has been investigated for multistranded retainers, there is a lack of data for novel CAD/CAM retainers. To address this, the present study compared the restriction of physiological tooth mobility in multistranded retainers and different CAD/CAM retainers.

MATERIAL/METHODS: One group of multistranded (n = 8) and five groups of CAD/CAM retainers (nickel-titanium (NiTi), titanium grade 5 (Ti5), polyetheretherketone (PEEK), zirconia (ZrO2), and cobalt-chromium (CoCr); each n = 8) bonded from canine to canine were investigated for their influence on vertical and horizontal tooth mobility using an in vitro model of a lower arch in a universal testing machine. Load-deflection curves were determined and statistically analysed.

RESULTS

All retainers restricted tooth mobility to varying extents. The retainers had less of an influence on vertical tooth mobility, with less of a difference between retainers (14%-38% restriction). In contrast, significant (P ≤ 0.05) differences were observed between retainers in the restriction of horizontal tooth mobility. ZrO2 retainers had the greatest impact, restricting horizontal tooth mobility by 82% (68 ± 20 µm/100N), followed by CoCr (75%, 94 ± 26 µm/100N) and PEEK (73%, 103 ± 28 µm/100N) CAD/CAM retainers, which had comparable effects on horizontal tooth mobility. Ti5 (54%, 175 ± 66 µm/100N) and NiTi (34%, 248 ± 119 µm/100N) CAD/CAM retainers had less of an influence on horizontal tooth mobility, and were comparable to multistranded retainers (44%, 211 ± 77 µm/100N).

LIMITATIONS

This is an in vitro study, so clinical studies are needed to draw clinical conclusions.

CONCLUSIONS

Multistranded and CAD/CAM retainers have different effects on tooth mobility in vitro. These effects should be further explored in future in vivo studies.

摘要

目的

正畸保持器应尽可能减少对生理性牙齿动度的限制。虽然多股保持器的这方面情况已有研究,但新型 CAD/CAM 保持器的数据仍缺乏。为解决这一问题,本研究比较了多股保持器和不同 CAD/CAM 保持器对生理性牙齿动度的限制作用。

材料/方法:本研究使用万能试验机的下颌弓体外模型,对 8 组多股(n = 8)和 5 组 CAD/CAM 保持器(镍钛(NiTi)、钛 5 级(Ti5)、聚醚醚酮(PEEK)、氧化锆(ZrO2)和钴铬(CoCr);每组 n = 8)分别从尖牙到尖牙粘结,研究它们对垂直和水平牙齿动度的影响。确定并对加载-挠度曲线进行了统计学分析。

结果

所有保持器都在不同程度上限制了牙齿移动。保持器对垂直牙齿移动的影响较小,各保持器之间的差异较小(14%-38%的限制)。相比之下,水平牙齿移动的限制中保持器之间存在显著差异(P ≤ 0.05)。ZrO2 保持器的影响最大,限制水平牙齿移动 82%(68 ± 20 µm/100N),其次是 CoCr(75%,94 ± 26 µm/100N)和 PEEK(73%,103 ± 28 µm/100N)CAD/CAM 保持器,它们对水平牙齿移动的影响相当。Ti5(54%,175 ± 66 µm/100N)和 NiTi(34%,248 ± 119 µm/100N)CAD/CAM 保持器对水平牙齿移动的影响较小,与多股保持器(44%,211 ± 77 µm/100N)相当。

局限性

这是一项体外研究,因此需要进行临床研究以得出临床结论。

结论

多股和 CAD/CAM 保持器对体外牙齿动度的影响不同。这些影响应在未来的体内研究中进一步探讨。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验