Baker R J, Bellen J C, Fornasiero D, Penglis S
Int J Rad Appl Instrum B. 1986;13(5):527-32. doi: 10.1016/0883-2897(86)90133-9.
The myocardial imaging agent technetium-99m-hexakis (tertiarybutylisonitrile) (99mTc-TBI) was prepared by the reaction of [99mTc]pertechnetate with TBI in 50% ethanol/0.9% saline at 100 degrees C, using stannous chloride as the reducing agent. A study of the reaction parameters enabled the yield to be optimized to better than 90%, although this was reduced to approximately 60% if a purification step was carried out. Chromatographic analysis on ITLC-SG medium showed the final product to be of high radiochemical purity. Biological studies comprising biodistribution in mice over a 2-h period, imaging studies in animals and sub-acute toxicity testing in mice indicated that 99mTc-TBI prepared as here described is a suitable agent for routine clinical use in humans.