Liu Hui, Fu Xinxing, Li Mohan, Wang Shuo
Department of Otolaryngology, Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing, China.
Key Laboratory of Otolaryngology, Head and Neck Surgery, Ministry of Education, Beijing Institute of Otolaryngology, Beijing, China.
Front Neurosci. 2023 Dec 21;17:1292395. doi: 10.3389/fnins.2023.1292395. eCollection 2023.
To investigate the correlation of air-conduction thresholds between automated audiometry in a non-isolated environment and manual audiometry in participants with normal hearing and different degrees of hearing loss.
Eighty-three participants aged 11-88 years old underwent automated pure-tone audiometry in a non-acoustically isolated environment, and the results were compared with those of manual pure-tone audiometry performed in a standard acoustically isolated booth, with the order of testing randomised. Six frequencies of 250, 500, 1,000, 2000, 4,000 and 8,000 Hz were tested.
All 166 ears were completed and 996 valid hearing threshold data were obtained, with 28 data exceeding the 95% confidence interval in the Bland-Altman plot, accounting for 2.81% of all data. The means and standard deviations of the differences for the six frequencies from 250 to 8,000 Hz were, respectively, 0.63 ± 5.31, 0.69 ± 4.50, 0.45 ± 4.99, 0.3 ± 6.2, -0.15 ± 4.8, and 0.21 ± 4.97 dB. The correlation coefficients of the two test results for normal hearing, mild, moderate, severe and above hearing loss groups were 0.95, 0.92, 0.97, and 0.96, respectively. The correlation coefficient of the automated and manual audiometry thresholds for the age groups under 40 years, 40-60 years, and 60 years above, were 0.98, 0.97 and 0.97, respectively, with all being statistically significant ( < 0.01). The response time of the three age groups were 791 ± 181 ms, 900 ± 190 ms and 1,063 ± 332 ms, respectively, and there was a significant difference between the groups under 40 years and over 60 years.
There was good consistency between automated pure-tone audiometry in a non-acoustically isolated environment and manual pure-tone audiometry in participants with different hearing levels and different age groups.
探讨在非隔离环境下自动听力测定与手动听力测定在听力正常及不同程度听力损失参与者中的气导阈值相关性。
83名年龄在11 - 88岁的参与者在非隔音环境下进行自动纯音听力测定,并将结果与在标准隔音室中进行的手动纯音听力测定结果进行比较,测试顺序随机。测试了250、500、1000、2000、4000和8000Hz六个频率。
共完成166只耳的测试,获得996个有效听力阈值数据,在Bland - Altman图中有28个数据超出95%置信区间,占所有数据的2.81%。250至8000Hz六个频率差异的均值和标准差分别为0.63±5.31、0.69±4.50、0.45±4.99、0.3±6.2、 - 0.15±4.8和0.21±4.97dB。听力正常、轻度、中度、重度及以上听力损失组两种测试结果的相关系数分别为0.95、0.92、0.97和0.96。40岁以下、40 - 60岁和60岁以上年龄组自动与手动听力测定阈值的相关系数分别为0.98、0.97和0.97,均具有统计学意义(<0.01)。三个年龄组的反应时间分别为791±181ms、900±190ms和1063±332ms,40岁以下组和60岁以上组之间存在显著差异。
在非隔音环境下的自动纯音听力测定与不同听力水平和不同年龄组参与者的手动纯音听力测定之间具有良好的一致性。