Björk-Shiley and Carpentier-Edwards valves. A comparative analysis.

作者信息

Nashef S A, Sethia B, Turner M A, Davidson K G, Lewis S, Bain W H

出版信息

J Thorac Cardiovasc Surg. 1987 Mar;93(3):394-404.

PMID:3821149
Abstract

Between January 1977 and December 1982, 986 Björk-Shiley and 744 Carpentier-Edwards valves were implanted in 774 and 620 patients, respectively, at the same institution. All Björk-Shiley patients and 57% of patients with a Carpentier-Edwards valve in the mitral position received long-term anticoagulation. Mean follow-up was 3.2 years (range 0 to 8.8) in the Björk-Shiley patients and 3.5 years (range 0 to 8.2) in the Carpentier-Edwards group. There was no significant difference between the two groups in hospital mortality (Björk-Shiley 7.6%; Carpentier-Edwards 6.0%), overall incidence of embolism (Björk-Shiley 1.4 per 100 patient-years; Carpentier-Edwards 1.6% py), endocarditis (Björk-Shiley 0.6% py; Carpentier-Edwards 0.8% py), periporsthetic leak (Björk-Shiley 1.6% py; Carpentier-Edwards 1.4% py), anticoagulant-related complications (Björk-Shiley 0.3% py; Carpentier-Edwards 0.1% py), valve failure (Björk-Shiley 0.78% py; Carpentier-Edwards 0.68% py), reoperation for complication (Björk-Shiley 1.68% py; Carpentier-Edwards 1.22% py), and late mortality (Björk-Shiley 3.1% py; Carpentier-Edwards 3.0% py). Actuarial freedom from valve-related events was similar in the two groups. In the aortic position, freedom from embolism was significantly better in the Björk-Shiley group than the Carpentier-Edwards group (Björk-Shiley 99% at 3 and 5 years; Carpentier-Edwards 96% and 92% at 3 and 5 years; p = 0.023). In the mitral position, the overall incidence of reoperation was higher in the Björk-Shiley group (1.78% py) than in the Carpentier-Edwards group (0.48% py) (p = 0.004). Actuarial analysis shows this difference to be confined to the first 6 years of follow-up. The commonest indication for reoperation was valve failure in both groups. However, when analysis is confined to this indication, the difference between the reoperation incidence in the mitral position becomes insignificant (Björk-Shiley 0.85% py; Carpentier-Edwards 0.29% py; p = 0.085). This study confirms the satisfactory performance of both the Carpentier-Edwards and Björk-Shiley valves in the short and middle term and indicates no clear-cut advantage for either prosthesis.

摘要

相似文献

1
Björk-Shiley and Carpentier-Edwards valves. A comparative analysis.
J Thorac Cardiovasc Surg. 1987 Mar;93(3):394-404.
2
Long-term comparative analysis of the Björk-Shiley and Hancock valves implanted in 1975.1975年植入的Björk-Shiley瓣膜和Hancock瓣膜的长期对比分析。
J Thorac Cardiovasc Surg. 1985 Nov;90(5):741-9.
3
Twelve-year comparison of a Bjork-Shiley mechanical heart valve with porcine bioprostheses.Bjork-Shiley机械心脏瓣膜与猪生物瓣膜的12年比较。
N Engl J Med. 1991 Feb 28;324(9):573-9. doi: 10.1056/NEJM199102283240901.
4
Comparative analysis of mechanical and bioprosthetic valves after aortic valve replacement.主动脉瓣置换术后机械瓣膜与生物瓣膜的对比分析
J Thorac Cardiovasc Surg. 1987 Jul;94(1):20-33.
5
Fourteen years' experience with the Björk-Shiley tilting disc prosthesis.使用比约克-希利倾斜盘式人工心脏瓣膜的十四年经验。
J Thorac Cardiovasc Surg. 1986 Mar;91(3):350-61.
6
Late results of valve replacement with the Björk-Shiley valve (1973 to 1982).使用Björk-Shiley瓣膜进行瓣膜置换的远期结果(1973年至1982年)。
J Thorac Cardiovasc Surg. 1993 Feb;105(2):302-12.
7
Comparative clinical results with Omniscience (STM1), Medtronic-Hall, and Björk-Shiley convexo-concave (70 degrees) prostheses in mitral valve replacement.二尖瓣置换术中使用Omniscience(STM1)、美敦力-霍尔和比约克-希利凸凹型(70度)人工瓣膜的临床结果比较。
J Thorac Cardiovasc Surg. 1986 Feb;91(2):174-83.
8
Aortic valve replacement with the Hancock standard, Björk-Shiley, and Lillehei-Kaster prostheses. A comparison based on follow-up from 1 to 15 years.采用汉考克标准型、比约克-希利型和 Lillehei-Kaster 型人工瓣膜进行主动脉瓣置换术。基于 1 至 15 年随访的比较。
J Thorac Cardiovasc Surg. 1989 Jul;98(1):37-47.
9
[Late complications following Björk-Shiley and Carpentier-Edwards heart valve replacements].
Z Kardiol. 1986 Jun;75(6):321-8.
10
Biological versus mechanical valves. Analysis of 1,116 valves inserted in 1,012 adult patients with a 4,818 patient-year and a 5,327 valve-year follow-up.
J Thorac Cardiovasc Surg. 1987 Feb;93(2):182-98.