OBJECTIVE

To analyze the effects of the angle between dynamic hip screw (DHS) and anti-rotation screw (AS) on vertically oriented femoral neck fractures (VOFNFs) and investigate the clinical results of them.

METHODS

Eighteen synthetic femurs were simulated and divided into 3 groups. The angle between DHS and AS in anteroposterior-view was marked as α, and in lateral-view was marked as β, thus the total angle (TA) was defined as the summation of α and β. The groups were categorized as group A (TA ≤ 5°), B (5° < TA ≤ 10°), and C (TA > 10°), respectively. All samples were tested under incremental, cyclical loading, and loading to failure. In clinic, 80 consecutive VOFNFs in 78 patients were treated with DHS plus AS. The patients were divided into 2 groups, including 48 fractures in parallel group (TA ≤10°) and 32 in angular group (TA >10°).

RESULTS

Group A and B survived during incremental and cyclical loading and endured longer than group C. Axial stiffness and failure loads were not different between group A and B, and greater than group C. Fracture gaps compressive stress was highest in group A, followed by group B and C. Forty-one fractures in parallel group and 23 in angular group healed at final follow-up. Nonunion and osteonecrosis occurred in 3 and 4 of parallel group, and 4 and 5 of angular group.

CONCLUSION

The construction with TA ≤10° between DHS and AS showed superior biomechanical performance and clinical results than those with TA >10°.

摘要

目的

分析动力髋螺钉(DHS)与抗旋螺钉(AS)之间的角度对垂直型股骨颈骨折(VOFNFs)的影响,并探讨其临床结果。

方法

模拟 18 个合成股骨,将其分为 3 组。DHS 与 AS 在前后位的夹角标记为α,在侧位的夹角标记为β,因此总角度(TA)定义为α和β的总和。将各组分别归类为 A 组(TA≤5°)、B 组(5°<TA≤10°)和 C 组(TA>10°)。所有样本均在递增、循环加载和失效加载下进行测试。在临床中,78 例患者的 80 例连续 VOFNFs 采用 DHS 加 AS 治疗。将患者分为两组,其中 48 例骨折在平行组(TA≤10°),32 例骨折在角度组(TA>10°)。

结果

A 组和 B 组在递增和循环加载过程中存活,且持续时间长于 C 组。轴向刚度和失效载荷在 A 组和 B 组之间没有差异,且大于 C 组。骨折间隙压缩应力在 A 组最高,其次是 B 组和 C 组。41 例平行组骨折和 23 例角度组骨折在最终随访时愈合。平行组中有 3 例和 4 例发生非愈合和骨坏死,角度组中有 4 例和 5 例发生非愈合和骨坏死。

结论

DHS 与 AS 之间的 TA≤10°的结构在生物力学性能和临床结果方面优于 TA>10°的结构。