Rehabilitation Medicine Center, The Second Affiliated Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, China.
School of Rehabilitation Medicine, Wenzhou Medical University, Wenzhou, Zhejiang, China.
Sports Health. 2024 Nov-Dec;16(6):923-930. doi: 10.1177/19417381231221716. Epub 2024 Jan 16.
Upper extremity (UE) dynamic balance is a significant physical fitness ability, which includes high-level neuromuscular proprioception, joint mobility, force, and coordination. The evaluation methods of UE dynamic balance are insufficient and lack experimental support. The Star Excursion Balance Test (SEBT) is a reliable assessment of dynamic balance and injury risk of the lower extremity.
The UE-SEBT is a reliable and reproducible approach for evaluating dynamic balance of UEs.
Observational study.
Level 4.
This cross-sectional study recruited 65 healthy adults. All participants were required to complete UE-SEBT, UE Y-balance test (UE-YBT), maximal voluntary isometric contraction (MVIC) of UE, closed kinetic chain UE stability test (CKCUEST), trunk flexor endurance test (TFET), trunk extensor endurance test (TEET), and lateral trunk endurance test (LTET). Intra- and inter-rater reliability and the correlation of UE-SEBT with other outcomes were measured.
Among the participants, the intra- and interoperator reliability of UE-SEBT in all directions and composite score achieved a moderate-to-excellent (intraclass correlation coefficients [ICC], 0.729-0.946) reliability. For validity, the UE-SEBT had a moderate to very strong correlation with UE-YBT ( = 0.315-0.755, < 0.01) and a strong correlation with CKCUEST ( = 0.4-0.67, < 0.01). Furthermore, the UE-SEBT performance showed weak-to-strong correlations with MVIC ( = 0.26-0.43, < 0.05). UE-SEBT was also correlated with LTET, TEET, and TFET to varying degrees.
UE-SEBT has good reliability and validity to assess UE dynamic balance compared with other tests.
UE-SEBT can be used as a clinical assessment method to evaluate UE dynamic balance and injury prevention.
上肢(UE)动态平衡是一项重要的身体适应能力,包括高级神经肌肉本体感觉、关节活动度、力量和协调性。UE 动态平衡的评估方法不足,缺乏实验支持。星型偏移平衡测试(SEBT)是一种可靠的评估下肢动态平衡和受伤风险的方法。
UE-SEBT 是一种可靠且可重复的 UE 动态平衡评估方法。
观察性研究。
4 级。
这项横断面研究招募了 65 名健康成年人。所有参与者都需要完成 UE-SEBT、UE Y 平衡测试(UE-YBT)、UE 最大自主等长收缩(MVIC)、闭合式运动链 UE 稳定性测试(CKCUEST)、躯干屈肌耐力测试(TFET)、躯干伸肌耐力测试(TEET)和侧躯干耐力测试(LTET)。测量了 UE-SEBT 的内部和外部可靠性以及与其他结果的相关性。
在参与者中,UE-SEBT 在所有方向和综合得分的内部和外部操作员可靠性均达到中等至优秀(组内相关系数 [ICC],0.729-0.946)。对于有效性,UE-SEBT 与 UE-YBT 具有中度至很强的相关性( = 0.315-0.755, < 0.01),与 CKCUEST 具有很强的相关性( = 0.4-0.67, < 0.01)。此外,UE-SEBT 表现与 MVIC 呈弱至强相关性( = 0.26-0.43, < 0.05)。UE-SEBT 还与 LTET、TEET 和 TFET 有不同程度的相关性。
与其他测试相比,UE-SEBT 具有良好的可靠性和有效性,可用于评估 UE 动态平衡。
UE-SEBT 可作为一种临床评估方法,用于评估 UE 动态平衡和预防受伤。