Suppr超能文献

八足平衡测试作为测量上肢工具的有效性、可靠性和可重复性与改良上四分之一 Y 平衡测试的比较。

Validity, Reliability and Reproducibility of OctoBalance Test as Tool to Measure the Upper Limb Compared to Modified-Upper Quarter Y-Balance Test.

机构信息

Facultad de Ciencias de la Salud, Universidad Europea del Atlántico, 39011 Santander, Spain.

Departamento de Salud, Universidad Internacional Iberoamericana, Campeche 24560, Mexico.

出版信息

Int J Environ Res Public Health. 2021 May 11;18(10):5057. doi: 10.3390/ijerph18105057.

Abstract

The articular evaluation of range of motion (ROM) is currently used to observe imbalance or limitations as possible risk factors or predispositions to suffer future injures. The main aim of this study is to verify the concurrent validity, reliability and reproducibility of the OctoBalance Test (OB) as a valid and reliable tool to measure articular ROM of the upper limb compared to the modified-Upper Quarter Y-Balance Test (mUQYBT). The twenty-five participants were male athletes. All of them were assessed with OB and mUQYBT in medial, superolateral, and inferolateral directions in both right and left arms with a three-minute break during these attempts. The process was repeated a second time with a week gap between measurements. Pearson correlation and linear logarithmic regression were used to examine the relationship between scores obtained with OB and mUQYBT. In order to verify the reliability, the intraclass correlation coefficient (ICC) was used (3.1). Concordance and reproducibility were assessed using Bland-Altman's graph. A perfect correlation and an almost linear logarithmic regression (R = 0.97) were observed between both measurement systems, with values of 73.531 ± 21.226 cm in mUQYBT and 69.541 ± 16.330 cm in OB. The differences were minimal between week one and week two. The assessment with Bland's graph showed the concordance and reproducibility of scores, showing the dispersion and the upper and lower limits. OB is shown as valid in comparison to the other test as a reliable and reproducible tool for the assessment of the articular ROM in the upper limb, and it could be used for the evaluation of injuries.

摘要

关节活动度(ROM)的评估目前用于观察不平衡或限制,作为可能的风险因素或易受伤的倾向。本研究的主要目的是验证 OctoBalance 测试(OB)与改良上四分之一 Y 平衡测试(mUQYBT)相比,作为测量上肢关节 ROM 的有效且可靠工具的同时效度、可靠性和可重复性。25 名参与者均为男性运动员。所有参与者均在右臂和左臂的内侧、外上侧和下外侧方向接受 OB 和 mUQYBT 评估,两次测试之间休息三分钟。在测量之间间隔一周后,第二次重复该过程。使用 Pearson 相关性和线性对数回归来检查 OB 和 mUQYBT 得分之间的关系。为了验证可靠性,使用组内相关系数(ICC)(3.1)。使用 Bland-Altman 图评估一致性和可重复性。两种测量系统之间观察到完美的相关性和几乎线性的对数回归(R = 0.97),mUQYBT 的值为 73.531 ± 21.226 cm,OB 的值为 69.541 ± 16.330 cm。第一周和第二周之间的差异很小。Bland 图的评估显示了分数的一致性和可重复性,显示了分散度和上下限。与其他测试相比,OB 被证明是一种有效的可靠且可重复的上肢关节 ROM 评估工具,可用于评估损伤。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/fcd8/8150945/8d7addb111d5/ijerph-18-05057-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验