基于分子印迹聚合物的电化学生物传感器用于选择性检测人血浆和尿液样品中毒剂 VX 代谢物乙基甲基膦酸。

Development of a molecularly imprinted polymer-based electrochemical sensor for the selective detection of nerve agent VX metabolite ethyl methylphosphonic acid in human plasma and urine samples.

机构信息

Department of Medical CBRN Defense, University of Health Sciences, Ankara, Türkiye.

Department of Analytical Chemistry, Gulhane Faculty of Pharmacy, University of Health Sciences, Ankara, Türkiye.

出版信息

Anal Bioanal Chem. 2024 Mar;416(6):1505-1515. doi: 10.1007/s00216-024-05155-6. Epub 2024 Jan 25.

Abstract

This study focuses on the detection of ethyl methyl phosphonic acid (EMPA), a metabolite of the banned organophosphorus nerve agent VX. We developed an electrochemical sensor utilizing the molecularly imprinted polymer (MIP) based on 4-aminobenzoic acid (4-ABA) and tetraethyl orthosilicate for the selective detection of EMPA in human plasma and urine samples. The 4-ABA@EMPA/MIP/GCE sensor was constructed by a thermal polymerization process on a glassy carbon electrode and sensor characterization was performed by cyclic voltammetry and electrochemical impedance spectroscopy. The 4-ABA@EMPA/MIP/GCE sensor demonstrated impressive linear ranges 1.0 × 10 M-2.5 × 10 M for the standard solution, 1.0 × 10 M-2.5 × 10 M for the urine sample, and 1.0 × 10 M-1 × 10 M of EMPA for the plasma sample with outstanding detection limits of 2.75 × 10 M (standard solution), 2.11 × 10 M (urine), and 2.36 × 10 M (plasma). The sensor exhibited excellent recovery percentages ranging from 99.86 to 101.30% in urine samples and 100.62 to 101.08% in plasma samples. These findings underscore the effectiveness of the 4-ABA@EMPA/MIP/GCE as a straightforward, highly sensitive, and selective interface capable of detecting the target analyte EMPA in human plasma and urine samples.

摘要

本研究专注于乙基甲基膦酸(EMPA)的检测,它是被禁用的有机磷神经毒剂 VX 的一种代谢物。我们开发了一种基于 4-氨基苯甲酸(4-ABA)和四乙氧基硅烷的分子印迹聚合物(MIP)电化学传感器,用于选择性检测人血浆和尿液样品中的 EMPA。4-ABA@EMPA/MIP/GCE 传感器通过在玻碳电极上的热聚合过程构建,并通过循环伏安法和电化学阻抗谱对传感器进行了表征。4-ABA@EMPA/MIP/GCE 传感器在标准溶液中展现出令人印象深刻的线性范围 1.0×10-5 M-2.5×10-5 M,在尿液样品中为 1.0×10-5 M-2.5×10-5 M,在血浆样品中为 1.0×10-5 M-1.0×10-4 M,检测限分别为 2.75×10-5 M(标准溶液)、2.11×10-5 M(尿液)和 2.36×10-5 M(血浆)。传感器在尿液样品中的回收率百分比范围为 99.86-101.30%,在血浆样品中的回收率百分比范围为 100.62-101.08%。这些发现突显了 4-ABA@EMPA/MIP/GCE 作为一种简单、高灵敏度和选择性的界面的有效性,能够检测人血浆和尿液样品中的目标分析物 EMPA。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/64a4/10861733/f97566747d34/216_2024_5155_Fig1_HTML.jpg