Suppr超能文献

开发和验证新的生物电阻抗方程,以准确估计白种人异质人群的体脂肪百分比。

Development and validation of new bioelectrical impedance equations to accurately estimate fat mass percentage in a heterogeneous Caucasian population.

机构信息

CTS-595 Research Group. Department of Informatics and Sports, Universidad Pablo de Olavide, Sevilla, Spain.

CTS-595 Research Group. Department of Informatics and Sports, Universidad Pablo de Olavide, Sevilla, Spain.

出版信息

Nutr Res. 2024 Mar;123:80-87. doi: 10.1016/j.nutres.2024.01.002. Epub 2024 Jan 10.

Abstract

Fat mass percentage (%FM) is frequently determined by nutritionists and personal trainers with bioelectrical impedance analysis (BIA) devices. The aims of the present study were: (1) to develop new regression equations using dual-energy X-ray absorptiometry (DXA) as the reference method for estimating %FM in a heterogeneous Caucasian population with a foot-to-hand device (BIA-101) and a hand-to-hand device (BIA-TELELAB) and (2) to compare the new equations with the manufacturers' equations. We hypothesized that the new equations would lead to more accurate estimations compared with DXA. A total of 218 healthy Caucasian participants aged 18 to 65 years were divided into a development group and a validation group. The accuracy of the different equations was assessed by mean differences, coefficient of determination, standard error of the estimate (SEE), intraclass correlation coefficients (ICC), and Bland-Altman plots. The proposed equation for BIA-101 explained 90.0% of the variance in the DXA-derived %FM, with a low random error (SEE = 2.98%), excellent agreement (ICC = 0.94), no fixed bias, and relatively low individual variability (5.86%). For BIA-TELELAB, the proposed equation explained 88.0% of the variance in the DXA-derived %FM, with a low random error (SEE = 3.27%), excellent agreement (ICC = 0.93), no fixed bias, and relatively low individual variability (6.37%). The results obtained for the manufacturers' equations confirm that these equations are not a good option for %FM assessment. As hypothesized, the new regression equations for BIA-101 and BIA-TELELAB devices can accurately estimate %FM in a heterogeneous Caucasian population with a broad age range.

摘要

体脂百分比(%FM)经常由营养师和私人教练使用生物电阻抗分析(BIA)设备来确定。本研究的目的是:(1)使用双能 X 射线吸收法(DXA)作为参考方法,为使用足部到手部设备(BIA-101)和手部到手部设备(BIA-TELELAB)的异质白种人群开发新的回归方程,以估算%FM;(2)将新方程与制造商的方程进行比较。我们假设与 DXA 相比,新方程将导致更准确的估计。共有 218 名年龄在 18 至 65 岁之间的健康白种人被分为开发组和验证组。通过平均差异、决定系数、估计标准误差(SEE)、组内相关系数(ICC)和 Bland-Altman 图评估不同方程的准确性。BIA-101 的建议方程解释了 DXA 衍生的%FM 方差的 90.0%,随机误差低(SEE=2.98%),一致性好(ICC=0.94),无固定偏差,个体差异相对较小(5.86%)。对于 BIA-TELELAB,建议的方程解释了 DXA 衍生的%FM 方差的 88.0%,随机误差低(SEE=3.27%),一致性好(ICC=0.93),无固定偏差,个体差异相对较小(6.37%)。制造商方程的结果证实,这些方程不是评估%FM 的好选择。正如假设的那样,BIA-101 和 BIA-TELELAB 设备的新回归方程可以在年龄范围广泛的异质白种人群中准确估计%FM。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验