Stockholm Doping Control Laboratory, Clinical Pharmacology Department, Karolinska University Hospital, Stockholm, Sweden.
Department of Laboratory Medicine, Karolinska Institutet, Stockholm, Sweden.
Drug Test Anal. 2024 Nov;16(11):1319-1322. doi: 10.1002/dta.3651. Epub 2024 Feb 6.
Recombinant human erythropoietin (rhEPO) has been abused as a performance enhancer in sports for several years, but with advancements in detection methods, even micro-doses can be detected in dried blood spot (DBS) samples. Here, we present the results from an Eporatio® (epoetin theta) micro-dose administration study to detect rhEPO in DBS samples. Five healthy male volunteers received a 15 IU/kg subcutaneous dose of Eporatio®. Urine and DBS samples (Mitra® VAMS and Capitainer® B50) were collected 1, 10, 24, 36, 48 and 72 h after drug administration. After 1 h, all urine samples were negative for rhEPO, whereas 40% of DBS samples were considered suspicious. All samples between 10 and 48 h were suspicious for the presence of Eporatio®, except one urine sample that was negative at 48 h. After 72 h, 40% of urine samples and 60% of DBS samples were suspicious and would have proceeded to a confirmation analysis. DBS is an efficient complementary matrix to urine for detection of rhEPO micro-doses.
重组人促红细胞生成素(rhEPO)多年来一直被滥用为运动中的性能增强剂,但随着检测方法的进步,即使是微量也可以在干血斑(DBS)样本中检测到。在这里,我们展示了一项 Eporatio®(促红素 theta)微剂量给药研究的结果,以检测 DBS 样本中的 rhEPO。五名健康男性志愿者接受了 15IU/kg 的皮下 Eporatio®剂量。给药后 1、10、24、36、48 和 72 小时收集尿液和 DBS 样本(Mitra®VAMS 和 Capitainer®B50)。给药后 1 小时,所有尿液样本均未检测到 rhEPO,而 40%的 DBS 样本被认为可疑。在 10 到 48 小时之间的所有样本均疑似存在 Eporatio®,除了一个在 48 小时时呈阴性的尿液样本。72 小时后,40%的尿液样本和 60%的 DBS 样本呈可疑状态,将进行确认分析。DBS 是检测 rhEPO 微量的一种有效的尿液补充基质。