Suppr超能文献

第三磨牙倾斜角度和磨牙后间隙在功能性正畸治疗后的变化:单块或赫斯特矫治器治疗后全景片的评估。

Third molar angulation and retromolar space after functional orthodontic treatment : Evaluation of panoramic radiographs after monoblock or Herbst appliance.

机构信息

Faculty of Dentistry, Department of Orthodontics, Akdeniz University, Antalya, Turkey.

出版信息

J Orofac Orthop. 2024 Aug;85(Suppl 2):181-188. doi: 10.1007/s00056-024-00516-3. Epub 2024 Feb 20.

Abstract

PURPOSE

The aim of this respectively cohort study was to evaluate the lower second and third molars and canine angulations, retromolar space and occlusal relationships after functional orthodontic treatments with the monoblock or Herbst appliance using panoramic radiographs.

METHODS

Pre- and posttreatment cephalometric and panoramic radiographs of 133 patients (mean age 13.89 ± 1.14 years) treated non-extraction with monoblock (n: 44), Herbst (n: 45) and fixed orthodontic appliances (control group; n: 44) were included to the study. Dental and skeletal measurements were performed on cephalometric radiographs. The angle between the third and second molars, and canines with the lower border of the mandible and the occlusal plane, gonial angle, the angle between the third and second molars and the retromolar space width were assessed on pre- and posttreatment panoramic radiographs. Paired and independent t tests were used for the statistical analysis of the data for intragroup and intergroup comparisons.

RESULTS

Functional treatment with both the monoblock and the Herbst appliances resulted in improvement of skeletal class II relationships. Retromolar space significantly increased in the functional appliance groups compared to the control group (p ≤ 0.001), but improvement of the angulations of posterior teeth was significant only in the monoblock group (p ≤ 0.001).

CONCLUSION

While both the Herbst and monoblock appliances led to an increase in retromolar space, monoblock treatment resulted in more favorable angulation of the third molars compared to the Herbst treatment.

摘要

目的

本研究旨在通过全景片评估使用单体或赫斯特矫治器进行功能性正畸治疗后下颌第二、第三磨牙及尖牙的倾斜度、磨牙后间隙和咬合关系。

方法

纳入 133 名(平均年龄 13.89±1.14 岁)非拔牙治疗的患者的治疗前和治疗后头颅侧位片和全景片,分别接受单体(n=44)、赫斯特(n=45)和固定矫治器(对照组;n=44)治疗。在头颅侧位片上进行牙性和骨性测量。在治疗前和治疗后的全景片上评估第三和第二磨牙、尖牙与下颌下缘和咬合平面之间的角度、下颌角、第三和第二磨牙之间的角度和磨牙后间隙的宽度。使用配对和独立 t 检验进行组内和组间数据的统计学分析。

结果

单体和赫斯特矫治器的功能性治疗均改善了骨性 II 类关系。与对照组相比,功能性矫治器组的磨牙后间隙显著增加(p≤0.001),但仅在单体组中后牙倾斜度有显著改善(p≤0.001)。

结论

虽然赫斯特和单体矫治器都导致磨牙后间隙增加,但与赫斯特治疗相比,单体治疗导致第三磨牙的倾斜度更有利。