The aim of this study was to analyze and compare the accuracy of a novel interproximal enamel reduction (IPR) technique based on a computer-aided static navigation technique with respect to a conventional free-hand-based technique for interproximal enamel reduction. Twenty anatomical-based experimental cast models of polyurethane were randomly distributed into the following IPR techniques: IPR technique based on computer-aided static navigation technique ( = 10) (GI) for Group A and conventional free-hand-based technique for the IPR ( = 10) (FHT) for Group B. The anatomical-based experimental cast models of polyurethane randomly assigned to the GI study group were submitted for a preoperative 3D intraoral surface scan; then, datasets were uploaded into 3D implant-planning software to design virtual templates for the interproximal enamel reduction technique. Afterward, the anatomical-based experimental cast models of polyurethane of both GI and FHT study groups were subjected to a postoperative digital impression by a 3D intraoral surface scan to compare the accuracy of the interproximal enamel reduction techniques at the buccal (mm), lingual/palatal (mm), and angular (◦) levels using the Student -test. Statistically significant differences between the interproximal enamel reduction technique based on the computer-aided static navigation technique and the conventional free-hand-based technique for the interproximal enamel reduction at the buccal ( = 0.0008) and lingual/palatal ( < 0.0001) levels; however, no statistically significant differences were shown at the angular level ( = 0.1042). The interproximal enamel reduction technique based on computer-aided static navigation technique was more accurate than the conventional free-hand-based technique for interproximal enamel reduction.
本研究的目的是分析和比较基于计算机辅助静态导航技术的新型邻面釉质磨除(IPR)技术与传统徒手邻面釉质磨除技术的准确性。将20个基于解剖结构的聚氨酯实验模型随机分为以下IPR技术组:A组为基于计算机辅助静态导航技术的IPR技术(n = 10)(GI),B组为传统徒手IPR技术(n = 10)(FHT)。随机分配到GI研究组的基于解剖结构的聚氨酯实验模型进行术前3D口内表面扫描;然后,将数据集上传到3D种植计划软件中,以设计邻面釉质磨除技术的虚拟模板。之后,GI和FHT研究组的基于解剖结构的聚氨酯实验模型均通过3D口内表面扫描进行术后数字印模,以使用Student检验比较邻面釉质磨除技术在颊侧(mm)、舌侧/腭侧(mm)和角度(°)水平的准确性。基于计算机辅助静态导航技术的邻面釉质磨除技术与传统徒手邻面釉质磨除技术在颊侧(P = 0.0008)和舌侧/腭侧(P < 0.0001)水平存在统计学显著差异;然而,在角度水平未显示出统计学显著差异(P = 0.1042)。基于计算机辅助静态导航技术的邻面釉质磨除技术比传统徒手邻面釉质磨除技术更准确。