Suppr超能文献

口内扫描仪记录颌间关系时,扫描范围和图像数量对记录精确度的影响。

Impact of scanning range and image count on the precision of digitally recorded intermaxillary relationships in interocclusal record using intraoral scanner.

机构信息

Department of Prosthodontics, School of Dentistry, Showa University.

出版信息

J Oral Sci. 2024 Apr 16;66(2):111-115. doi: 10.2334/josnusd.23-0379. Epub 2024 Feb 23.

Abstract

PURPOSE

The effect of scan range and the number of scanned images on the precision of in vivo intermaxillary relationship reproduction was evaluated using digital scans acquired with an intraoral scanner.

METHODS

The study involved 15 participants with normal occlusion. Two different interocclusal recording settings were employed using the intraoral scanner (TRIOS 4): 'MIN,' focusing on the minimal scan range of the first molar region, and 'MAX,' including the scan range from the right first premolar to the right second molar. These settings were combined with three different image counts, resulting in six experimental conditions. Interocclusal recordings were performed four times for each condition. Dimensional discrepancies between datasets were analyzed using three-dimensional morphometric software and compared using two-way analysis of variance.

RESULTS

Median dimensional discrepancies (interquartile range; IQR) of 39.2 (30.7-49.4), 42.2 (32.6-49.3), 30.3 (26.8-44.1), 20.1 (16.0-34.8), 21.8 (19.0-25.1), and 26.6 (19.9-34.5) µm were found for MIN/200, MIN/400, MIN/600, MAX/200, MAX/400, and MAX/600, respectively. Significant differences in dimensional discrepancies according to scan range were found. Wilcoxon signed-rank test showed significant differences between MAX and MIN (P < 0.01).

CONCLUSION

Scan range may affect the precision of intermaxillary relationship reproduction. Thus, scanning of the most extensive region practically achievable is recommended.

摘要

目的

本研究旨在通过使用口内扫描仪获取的数字扫描,评估扫描范围和扫描图像数量对体内颌间关系再现精度的影响。

方法

本研究纳入了 15 名正常咬合的参与者。使用口内扫描仪(TRIOS 4)采用两种不同的颌间记录设置:“MIN”,关注第一磨牙区域的最小扫描范围;“MAX”,包括从右侧第一前磨牙到右侧第二磨牙的扫描范围。这两种设置与三种不同的图像数量相结合,共产生了六种实验条件。对于每种条件,都进行了四次颌间记录。使用三维形态计量学软件分析数据集之间的尺寸差异,并使用双向方差分析进行比较。

结果

MIN/200、MIN/400、MIN/600、MAX/200、MAX/400 和 MAX/600 的中位数尺寸差异(四分位距;IQR)分别为 39.2(30.7-49.4)、42.2(32.6-49.3)、30.3(26.8-44.1)、20.1(16.0-34.8)、21.8(19.0-25.1)和 26.6(19.9-34.5)µm。根据扫描范围,尺寸差异存在显著差异。Wilcoxon 符号秩检验显示 MAX 和 MIN 之间存在显著差异(P < 0.01)。

结论

扫描范围可能会影响颌间关系再现的精度。因此,建议扫描尽可能广泛的区域。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验