Institute of Laboratory Medicine, Cantonal Hospital Aarau, Tellstrasse 25, 5001 Aarau, Switzerland; Division of Clinical Pharmacy and Epidemiology, Department of Pharmaceutical Sciences, University of Basel, Spitalstrasse 26, 4056 Basel, Switzerland; Department of Diabetes, Endocrinology, Nutritional Medicine and Metabolism (UDEM), Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 15, 3010 Bern, Switzerland.
Institute of Laboratory Medicine, Cantonal Hospital Aarau, Tellstrasse 25, 5001 Aarau, Switzerland.
Clin Nutr. 2023 Dec;42(12):2475-2483. doi: 10.1016/j.clnu.2023.10.012. Epub 2023 Oct 19.
BACKGROUND & AIMS: Parenteral nutrition (PN) can lead to high or even toxic exposure to aluminum (Al). We aimed to quantify concentrations of Al and other chemical elements of all-in-one (AIO) PN admixtures for adults prepared from commercial multichamber bags (Olimel® 5.7%, Omegaflex® special, SmofKabiven®, all with and without electrolytes) and vitamin and trace element additives over a 48-h period. Secondly, we determined the level of Al contamination resulting from admixing and infusion set use.
We used dynamic reaction cell and kinetic energy discrimination inductively coupled plasma mass spectrometry (ICP-MS) to quantify Al, arsenic (As), cadmium (Cd), cobalt (Co), chromium (Cr), copper (Cu), iron (Fe), magnesium (Mg), manganese (Mn), molybdenum (Mo), nickel (Ni), antimony (Sb), selenium (Se), tin (Sn), vanadium (V), and zinc (Zn) in AIO PN admixtures. We extracted samples for analysis via the bag injection ports and infusion sets over a 48-h period after admixing. We compared the measured Al concentrations of AIO PN admixtures with calculated values based on the measured concentrations of individual chamber contents and additives.
Mean (standard deviation) baseline Al concentrations in AIO PN admixtures ranged from 10.5 (0.5) to 59.3 (11.4) μg/L and decreased slightly over the 48 h (estimate [standard error] -0.09 [0.02] μg/L/hour, p <0.001). Thus, certain products exceeded the widely accepted limit of 25 μg/L. There was no significant difference in Al concentrations between samples extracted via the bag injection ports or infusion sets (p = 0.33), nor between measured and calculated Al concentrations of AIO PN admixtures (p = 0.91).
Because certain commercially available PN admixtures for adults proved to contain excessively high levels of Al in our study, regulations and corresponding quality requirements at the authority level (e.g., Pharmacopoeia and regulatory authorities) are urgently required. Our results showed that the PN handling process (admixing and supplementing additives) or the materials of the infusion set did not lead to additional Al contamination to any extent. Moreover, calculated Al concentrations of AIO PN admixtures derived from individual chamber contents and additives are valid.
肠外营养(PN)可导致铝(Al)的高暴露甚至毒性暴露。我们旨在定量分析来自商业多腔袋(Olimel®5.7%、Omegaflex®特殊、SmofKabiven®,均有或无电解质)的成人全合一(AIO)PN 添加剂以及维生素和微量元素添加剂的 Al 和其他化学元素浓度,时间跨度为 48 小时。其次,我们确定了混合和输液套件使用过程中导致 Al 污染的程度。
我们使用动态反应池和动能分辨电感耦合等离子体质谱法(ICP-MS)定量分析 AIO PN 添加剂中的 Al、砷(As)、镉(Cd)、钴(Co)、铬(Cr)、铜(Cu)、铁(Fe)、镁(Mg)、锰(Mn)、钼(Mo)、镍(Ni)、锑(Sb)、硒(Se)、锡(Sn)、钒(V)和锌(Zn)。我们通过混合后 48 小时内的袋注入口和输液套件提取样品进行分析。我们将 AIO PN 添加剂的实测 Al 浓度与基于各腔室内容物和添加剂实测浓度计算的浓度进行了比较。
AIO PN 添加剂的平均(标准差)基线 Al 浓度范围为 10.5(0.5)至 59.3(11.4)μg/L,在 48 小时内略有下降(估计[标准误差]-0.09[0.02]μg/L/小时,p<0.001)。因此,某些产品超过了广泛接受的 25μg/L 限值。通过袋注入口或输液套件提取的样品之间的 Al 浓度无显著差异(p=0.33),AIO PN 添加剂的实测和计算 Al 浓度之间也无显著差异(p=0.91)。
由于某些市售的成人 PN 添加剂在我们的研究中被证明含有过高水平的 Al,因此迫切需要在管理机构层面制定法规和相应的质量要求(如《药典》和监管机构)。我们的结果表明,PN 处理过程(混合和添加添加剂)或输液套件的材料并未导致任何程度的额外 Al 污染。此外,来自各腔室内容物和添加剂的 AIO PN 添加剂的计算 Al 浓度是有效的。