Riera Carme, Karasan Duygu, Sailer Irena, Mojon Phillipe, Fehmer Vincent, Pitta João
Division of Fixed Prosthodontics and Biomaterials, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland.
Clin Oral Implants Res. 2024 Aug;35(8):1042-1053. doi: 10.1111/clr.14251. Epub 2024 Feb 28.
Investigate survival and technical complications of two-unit posterior implant-supported cantilever made of monolithic zirconia on titanium-base abutments (Zr-TiB) vs. porcelain-fused-to-metal on castable gold abutments (PFM-GA) using two different implant connections, internal butt-joint (IBJ) and internal conical (IC).
Forty-eight implants (4.3 mm diameter) were divided into four groups (n = 12) to support 2-unit mandibular premolar cantilevers with two different materials (Zr-TiB vs. PFM-GA) and two connection types (IBJ vs. IC). Tested groups were as follows: (1) IBJ/Zr-TiB; (2) IBJ/PFM-GA; (3) IC/Zr-TiB; and (4) IC/PFM-GA. Specimens were thermomechanical aged (1,200,000 cycles, 98 N, 5-55°C) with occlusal axial load on the pontic. Catastrophic and non-catastrophic events were registered, and removal torque values measured before and after aging. Specimens surviving aging were subjected to loading until failure. Survival, total complication rates, torque loss (%), and bending moments were calculated.
From 48 specimens, 38 survived aging. Survival rates significantly varied from 16.7% (IC/PFM-GA) to 100% (IBJ/Zr-TiB; IBJ/PFM-GA; IC/Zr-TiB) (p < .01). Internal conical connection revealed significantly higher torque loss (IC/ZrTiB - 67%) compared to internal butt-joint (IBJ/Zr-TiB - 44%; IBJ/PFM-GA - 46%) (p < .01). Bending moments were higher in internal butt-joint connections than in internal conical (p < .05).
Two-unit posterior implant-supported cantilever FDPs replacing mandibular premolars composed of monolithic zirconia on titanium-base abutments demonstrated higher mechanical stability compared to porcelain-fused-to-metal on castable gold abutments in this in vitro study. The internal conical connection combined with porcelain-fused-to-metal on gold abutments revealed a high number of failures; therefore, their clinical use may be considered cautiously for this indication.
研究在钛基台上由整体式氧化锆制成的两单位后牙种植体支持悬臂(Zr-TiB)与在可铸造金基台上的烤瓷熔附金属(PFM-GA),采用两种不同种植体连接方式(内部对接(IBJ)和内部锥形(IC))的生存率和技术并发症。
48颗种植体(直径4.3毫米)分为四组(n = 12),以支持两单位下颌前磨牙悬臂,采用两种不同材料(Zr-TiB与PFM-GA)和两种连接类型(IBJ与IC)。测试组如下:(1)IBJ/Zr-TiB;(2)IBJ/PFM-GA;(3)IC/Zr-TiB;(4)IC/PFM-GA。标本进行热机械老化(1,200,000次循环,98 N,5 - 55°C),在桥体上施加咬合轴向载荷。记录灾难性和非灾难性事件,并在老化前后测量拆除扭矩值。老化后存活的标本进行加载直至失效。计算生存率、总并发症发生率、扭矩损失(%)和弯矩。
48个标本中,38个老化后存活。生存率从16.7%(IC/PFM-GA)到100%(IBJ/Zr-TiB;IBJ/PFM-GA;IC/Zr-TiB)有显著差异(p <.01)。与内部对接连接(IBJ/Zr-TiB - 44%;IBJ/PFM-GA - 46%)相比,内部锥形连接显示出显著更高的扭矩损失(IC/ZrTiB - 67%)(p <.01)。内部对接连接中的弯矩高于内部锥形连接(p <.05)。
在这项体外研究中,与在可铸造金基台上的烤瓷熔附金属相比,由钛基台上的整体式氧化锆组成的两单位后牙种植体支持悬臂固定局部义齿替代下颌前磨牙显示出更高的机械稳定性。内部锥形连接与金基台上的烤瓷熔附金属相结合显示出大量失败;因此,对于该适应证,其临床应用可能需要谨慎考虑。