Suppr超能文献

角kappa与多焦点人工晶状体植入术后患者报告的结局无关。

Angle Kappa is Not Correlated with Patient-Reported Outcomes After Multifocal Lens Implantation.

作者信息

Liu Xi, Hannan Stephen J, Schallhorn Steven C, Schallhorn Julie M

机构信息

Southwest Hospital/Southwest Eye Hospital, Third Military Medical University (Army Military Medical University), Chongqing, People's Republic of China.

Key Laboratory of Visual Damage and Regeneration & Restoration in Chongqing, Chongqing, People's Republic of China.

出版信息

Clin Ophthalmol. 2024 Feb 26;18:605-612. doi: 10.2147/OPTH.S452147. eCollection 2024.

Abstract

PURPOSE

To examine the effect of preoperative angle kappa on patient-reported outcomes after multifocal lens placement during cataract surgery and determine if it is an effective measure for preoperative patients screening for multifocal lens placement.

SETTING

Private refractive surgery clinics.

DESIGN

Retrospective cohort study.

METHODS

All patients undergoing bilateral cataract or refractive lens exchange surgery with a target of emmetropia between 2013 and 2017 at Optical Express (Glasgow, UK) with multifocal lens placement for whom preoperative angle kappa measurement and a postoperative month 1 patient-reported outcomes measures were available were included.

RESULTS

A total of 1368 patients were identified. Median preoperative angle kappa was 0.41mm with an interquartile range of 0.30mm to 0.53mm. Preoperative angle kappa did not have a significant association with patient-reported satisfaction with vision (correlation coefficient 0.15, 95% confidence interval -0.081 to 0.39, = 0.20) nor with patient-reported photic phenomena ( > 0.09 for all comparisons). A receiver-operator characteristic analysis did not yield a viable cutoff predictive of patient-reported satisfaction.

CONCLUSION

Angle kappa was not predictive of patient-reported satisfaction in this study. This study did not find evidence that it should be used as a screening test for patients considering multifocal intraocular lens placement.

摘要

目的

研究术前kappa角对白内障手术中植入多焦点人工晶状体后患者报告结局的影响,并确定其是否为术前筛选多焦点人工晶状体植入患者的有效指标。

设置

私立屈光手术诊所。

设计

回顾性队列研究。

方法

纳入2013年至2017年期间在英国格拉斯哥的Optical Express接受双侧白内障或屈光性晶状体置换手术、目标为正视、植入多焦点人工晶状体且有术前kappa角测量值和术后1个月患者报告结局测量值的所有患者。

结果

共识别出1368例患者。术前kappa角中位数为0.41mm,四分位间距为0.30mm至0.53mm。术前kappa角与患者报告的视力满意度(相关系数0.15,95%置信区间-0.081至0.39,P = 0.20)以及患者报告的畏光现象均无显著相关性(所有比较的P>0.09)。受试者工作特征分析未得出预测患者报告满意度的可行临界值。

结论

在本研究中,kappa角不能预测患者报告的满意度。本研究未发现证据表明应将其用作考虑植入多焦点人工晶状体患者的筛选测试。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/95af/10906724/64c58a23f848/OPTH-18-605-g0001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验