Suppr超能文献

植入三焦点人工晶状体后kappa角对临床结果和患者报告结局的影响。

The Effects of Angle Kappa on Clinical Results and Patient-Reported Outcomes After Implantation of a Trifocal Intraocular Lens.

作者信息

Sandoval Helga P, Potvin Richard, Solomon Kerry D

机构信息

Carolina Eyecare Physicians, LLC, Mt. Pleasant, SC, USA.

Science in Vision, Bend, OR, USA.

出版信息

Clin Ophthalmol. 2022 Apr 27;16:1321-1329. doi: 10.2147/OPTH.S363536. eCollection 2022.

Abstract

PURPOSE

To objectively determine if angle kappa materially influenced clinical outcomes or patient-reported satisfaction and visual quality of patients implanted with a trifocal intraocular lens (IOL).

METHODS

This was a non-interventional study of clinical outcomes. Subjects were patients choosing to be bilaterally implanted with a trifocal IOL (PanOptix) who were then evaluated 3 months postoperative. Angle kappa (AK) was measured before surgery and at the 3-month visit. The 3-month visit included a manifest refraction, and measurement of uncorrected and distance corrected acuity at 4 m, 60 cm and 40 cm. Visual quality and satisfaction questionnaires were also administered.

RESULTS

Data from 56 eyes of 28 subjects were analyzed; 26 eyes had an AK magnitude <0.3 mm, 14 had an AK from 0.3 mm to less than 4 mm and 16 had an AK ≥0.4 mm. Neither visual disturbances (eg, glare, halos, starbursts), satisfaction nor spectacle dependence were correlated to the magnitude of angle kappa. The magnitude of postoperative AK was significantly lower than preoperative (0.24 ± 0.12 mm vs 0.30 ± 0.16 mm, p < 0.01).

CONCLUSION

The magnitude of preoperative Angle Kappa had no apparent effect on the refractive, visual acuity or subjective (visual disturbances, quality of vision, satisfaction) clinical outcomes with this trifocal IOL. The magnitude of angle kappa was significantly lower after surgery.

摘要

目的

客观确定kappa角是否对三焦点人工晶状体(IOL)植入患者的临床结局、患者报告的满意度和视觉质量产生实质性影响。

方法

这是一项关于临床结局的非干预性研究。研究对象为选择双侧植入三焦点IOL(PanOptix)的患者,术后3个月进行评估。术前及术后3个月访视时测量kappa角(AK)。术后3个月访视包括验光,以及测量4米、60厘米和40厘米处的未矫正视力和远距矫正视力。还进行了视觉质量和满意度问卷调查。

结果

分析了28名受试者56只眼的数据;26只眼的AK值<0.3毫米,14只眼的AK值在0.3毫米至小于4毫米之间,16只眼的AK值≥0.4毫米。视觉干扰(如眩光、光晕、星芒)、满意度或对眼镜的依赖程度均与kappa角大小无关。术后AK值显著低于术前(0.24±0.12毫米对0.30±0.16毫米,p<0.01)。

结论

术前kappa角大小对这种三焦点IOL的屈光、视力或主观(视觉干扰、视觉质量、满意度)临床结局无明显影响。术后kappa角大小显著降低。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3902/9058245/72982678f50a/OPTH-16-1321-g0001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验