Odontology. 2024 Oct;112(4):1167-1177. doi: 10.1007/s10266-024-00924-2. Epub 2024 Mar 21.
To evaluate the impact on the quality of filling with of low-fusion and conventional gutta-percha cones. Thirty-six maxillary canines were prepared and divided into three groups: I-conventional cone with Downpack at 200 °C at 4 mm from the WL; II-low-fusion cone with Downpack at 100 °C up to 4 mm from the WL; III-low-fusion cone with Downpack at 100 °C up to 7 mm from the WL. Temperature variations were measured in thirds on the external surface of the root. The bond strength was evaluated using the push-out test. The adhesive interface was analyzed by scanning electron microscopy. The bond strength and the temperature variation data were analyzed using analysis of variance and the failure type using the chi-square test. The low-fusion cone group with 7 mm Downpack showed higher bond strength (4.2 ± 2.7) compared with conventional cones (2.8 ± 1.6) and low-fusion cones with 4 mm Downpack (2.9 ± 1.6) (p < 0.05), with occurrence of a higher number of adhesive failures to the filling material and mixed failures. Relative to temperature variation, there was less temperature change in the apical third, in the low-fusion cone with Downpack 7 mm (1.0 ± 1.0) (p < 0.05). The use of low-fusion cones allowed the continuous wave condensation technique to be performed at a lower depth of Downpack at 100 °C at 7 mm, with less heating in the apical third, without compromising the quality of filling. Using gutta-percha cones with low fusion, which permits a lower condensation temperature and reduced Downpack depth, maintains the quality of filling, in order to minimize possible damage to the periapical tissues.
评估低温熔融和传统牙胶尖对充填质量的影响。将 36 颗上颌尖牙分为三组:I-常规牙胶尖,用 Downpack 在距 WL 4mm 处加热至 200°C;II-低温熔融牙胶尖,用 Downpack 在距 WL 4mm 处加热至 100°C;III-低温熔融牙胶尖,用 Downpack 在距 WL 7mm 处加热至 100°C。测量根外表面的温度变化,在三分之一处进行测量。使用推出试验评估粘结强度。使用扫描电子显微镜分析粘结界面。使用方差分析评估粘结强度和温度变化数据,使用卡方检验评估失效类型。7mm Downpack 的低温熔融牙胶尖组的粘结强度(4.2±2.7)高于常规牙胶尖组(2.8±1.6)和 4mm Downpack 的低温熔融牙胶尖组(2.9±1.6)(p<0.05),且发生较多的粘结剂向充填材料和混合性破坏。与温度变化相比,在 7mm Downpack 的低温熔融牙胶尖中,根尖三分之一的温度变化较小(1.0±1.0)(p<0.05)。使用低温熔融牙胶尖可在 100°C 时,7mm 深度的 Downpack 处进行连续波压缩技术,根尖三分之一处的加热减少,而不会影响充填质量。使用低温熔融牙胶尖,可降低压缩温度和减少 Downpack 深度,保持充填质量,以尽量减少对根尖组织的潜在损害。