Suppr超能文献

2024 年 2 月,源自自动婴儿配奶机水箱的新生儿脑膜炎,荷兰。

Neonatal meningitis originating from the water reservoir of an automated infant milk dispenser, the Netherlands, February 2024.

机构信息

University Medical Center Groningen, Department of Paediatric Infectious Diseases and Immunity, Groningen, the Netherlands.

These authors contributed equally to this work and share first/last authorship.

出版信息

Euro Surveill. 2024 Apr;29(14). doi: 10.2807/1560-7917.ES.2024.29.14.2400177.

Abstract

is a multidrug-resistant pathogen causing high mortality and morbidity in adults with comorbidities and neonates. We report a Dutch case of meningitis in a neonate, clonally related to samples taken from an automated infant milk dispenser located at the family's residence. We inform about the emergence of and suggest molecular surveillance in hospitals and other health settings. This is the first case connecting an automated formula dispenser to an invasive infection in a neonate.

摘要

是一种多药耐药病原体,可导致合并症成年人和新生儿的高死亡率和发病率。我们报告了一例荷兰新生儿脑膜炎病例,该病例与从家庭住所的自动婴儿奶粉分配器中采集的样本具有克隆相关性。我们介绍了 的出现,并建议在医院和其他卫生环境中进行分子监测。这是首例将自动配方分配器与新生儿侵袭性感染联系起来的病例。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/e98d/11004591/c0b442e0a65c/2400177-f1.jpg