Vas Nazleen V, Varghese Remmiya Mary
Orthodontics and Dentofacial Orthopaedics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, IND.
Cureus. 2024 Mar 10;16(3):e55911. doi: 10.7759/cureus.55911. eCollection 2024 Mar.
Background Attachments play a vital role in aligner-led orthodontic therapy, first passively through retention of the appliance and secondly, through bringing about tooth movement, by virtue of its active surfaces, to achieve treatment goals. Additionally, irregularities on the surface of attachments attract plaque adhesion. Thus the effect of brushing with different toothbrushes on the surface of attachments is an important factor to study. This would allow clinicians to better advise patients who are undergoing aligner therapy. Four types of brushes are available commercially, namely hard, medium, soft, and ultra-soft. This study analyses the interaction between the kind of toothbrush used and the wear of the surface of the aligner attachment, to understand the impact of a toothbrush on the attachment. Aim To observe the surface wear and change in the shape of the aligner attachment on brushing with four varying hardness of toothbrush bristle (ultra-soft, soft, medium, and hard) over six months to three years. Material and methods One attachment was bonded to the buccal surface of extracted premolars. One tooth with attachment was subjected to SEM analysis and the rest were divided into four groups of five teeth each, based on the type of toothbrush to be used. Brushing with hard, medium, soft, and ultra-soft toothbrushes was carried out in a brushing simulator in two cycles simulating six months, one year, 18 months, and three years of brushing. A contact profilometer was used to evaluate surface roughness before and after brushing and pre- and post-surface roughness values were compared to quantitate changes after which SEM analysis was carried out for qualitative assessment of the surface of the samples. The Shapiro-Wilks test was applied to evaluate the normality of the data, followed by the one-way ANOVA, and statistical significance was applied at p<0.05. Results At six months, the samples brushed with the medium toothbrush showed the least surface roughness (0.2±0.192) and those brushed with the ultra-soft toothbrushes showed the highest surface roughness (1.9±0.159). At one year, the samples brushed with the soft toothbrush showed the least surface roughness (0.46 ±0.31) and those brushed with the ultra-soft toothbrushes showed the highest surface roughness (2.12 ±0.12). At the 1.5-year point, the surface roughness of the samples was lowest in the ultra-soft toothbrush group (0.43±0.39) and the highest in the soft toothbrush group (1.6± 0.41). At the three-year point, the surface roughness of the samples was lowest in the ultra-soft toothbrush group (0.28 ± 0.17) and the highest in the medium toothbrush group (1.6 ± 0.31). Conclusion Ultra-soft toothbrushes have a high abrasive potential, as seen by higher surface roughness values over six months and one year. Morphometric changes were the most noticeable for attachments brushed by hard-bristled toothbrushes and medium-bristled brushes.
背景
附件在隐形矫治器正畸治疗中起着至关重要的作用,首先通过被动方式固定矫治器,其次通过其作用面实现牙齿移动,以达成治疗目标。此外,附件表面的不平整会吸引牙菌斑附着。因此,使用不同牙刷对附件表面进行刷牙的效果是一个需要研究的重要因素。这将有助于临床医生更好地为正在接受隐形矫治治疗的患者提供建议。市面上有四种类型的牙刷,即硬毛、中毛、软毛和超软毛牙刷。本研究分析了所使用牙刷类型与隐形矫治附件表面磨损之间的相互作用,以了解牙刷对附件的影响。
目的
观察使用四种不同硬度刷毛(超软、软、中、硬)的牙刷刷牙六个月至三年后,隐形矫治附件的表面磨损及形状变化。
材料和方法
将一个附件粘结到拔除的前磨牙颊面。对一个带有附件的牙齿进行扫描电子显微镜(SEM)分析,其余牙齿根据所使用的牙刷类型分为四组,每组五颗牙齿。在刷牙模拟器中,以模拟六个月、一年、18个月和三年刷牙的两个周期,分别用硬毛牙刷、中毛牙刷、软毛牙刷和超软毛牙刷进行刷牙。使用接触式轮廓仪评估刷牙前后的表面粗糙度,并比较刷牙前后的表面粗糙度值以量化变化情况,之后进行SEM分析以对样品表面进行定性评估。应用夏皮罗-威尔克检验评估数据的正态性,随后进行单因素方差分析,统计学显著性设定为p<0.05。
结果
在六个月时,使用中毛牙刷刷牙的样品表面粗糙度最小(0.2±0.192),而使用超软毛牙刷刷牙的样品表面粗糙度最大(1.9±0.159)。在一年时,使用软毛牙刷刷牙的样品表面粗糙度最小(0.46±0.31),使用超软毛牙刷刷牙的样品表面粗糙度最大(2.12±0.12)。在1.5年时,超软毛牙刷组样品的表面粗糙度最低(0.43±0.39),软毛牙刷组最高(1.6±0.41)。在三年时,超软毛牙刷组样品的表面粗糙度最低(0.28±0.17),中毛牙刷组最高(1.6±0.31)。
结论
超软毛牙刷具有较高的磨损潜力,从六个月和一年期间较高的表面粗糙度值可以看出。硬毛牙刷和中毛牙刷刷牙的附件形态变化最为明显。