IDDSI 漏斗法用于液体流量测试的验证。

Validation of the IDDSI funnel for liquid flow testing.

机构信息

International Dysphagia Diet Standardisation Initiative, Vancouver, Canada.

KITE Research Institute-University Health Network, Toronto, Canada.

出版信息

J Texture Stud. 2024 Apr;55(2):e12823. doi: 10.1111/jtxs.12823.

Abstract

In 2017, the International Dysphagia Diet Standardisation Initiative (IDDSI) introduced the IDDSI flow test which enables patients, clinicians, caregivers, food service professionals and researchers to classify liquid thickness into five levels based on the volume of liquid remaining in a standard 10 mL slip tip syringe after 10 s of flow under gravity. Within a few months of publishing the IDDSI flow test instructions, several barriers emerged: (1) the preferred model of syringe (BD 303134) was not equally accessible around the world, causing some users to perform flow tests with alternate models of syringe; (2) differences in syringe geometry across models led to variations in IDDSI flow test results; and (3) the need to use a second syringe for sample loading added complexity and cost to end users. To address these barriers, IDDSI designed the IDDSI funnel, a novel device, which combines the geometry of the BD 303134 syringe with a kitchen funnel to facilitate easy loading of liquid samples without need for a second syringe. In this report, we compare the IDDSI flow test results across two devices: syringe BD 303134 and IDDSI funnel. IDDSI level classifications were in complete agreement with the syringe reference test results in 67/73 (92%) of the test fluids and temperature conditions with mean difference of residual liquid across devices of 0.2 (2% full scale). These results demonstrate excellent correspondence between the two devices.

摘要

2017 年,国际吞咽障碍饮食标准化倡议(IDDSI)引入了 IDDSI 流动测试,使患者、临床医生、护理人员、餐饮服务专业人员和研究人员能够根据重力作用下 10 秒内标准 10 毫升滑管注射器中剩余液体的体积,将液体稠度分为五个等级。在发布 IDDSI 流动测试说明后的短短几个月内,出现了几个障碍:(1)首选的注射器模型(BD 303134)在全球并非同等普及,导致一些使用者使用替代注射器模型进行流动测试;(2)不同模型的注射器几何形状差异导致 IDDSI 流动测试结果存在差异;(3)需要使用第二个注射器进行样品加载,给最终用户增加了复杂性和成本。为了解决这些障碍,IDDSI 设计了 IDDSI 漏斗,这是一种新颖的装置,它结合了 BD 303134 注射器的几何形状和厨房漏斗,便于轻松加载液体样品,无需使用第二个注射器。在本报告中,我们比较了两种装置的 IDDSI 流动测试结果:注射器 BD 303134 和 IDDSI 漏斗。在 67/73(92%)种测试液体和温度条件下,IDDSI 级别分类与注射器参考测试结果完全一致,两种装置之间的残留液体平均差异为 0.2(满刻度的 2%)。这些结果表明两种装置之间具有极好的一致性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验