Suppr超能文献

羟丙基胍滴眼液在控制干燥环境下两种治疗方法改善泪膜指数和眼表面动力学的疗效。

Efficacy of hydroxypropyl-guar drops in improving tear film index and ocular surface dynamics using two treatment methods under a controlled desiccating environment.

机构信息

Department of Optometry, College of Applied Medical Sciences, King Saud University, 12372, Riyadh, Saudi Arabia.

Department of Vision Science, School of Health and Life Sciences, Glasgow Caledonian University, 70 Cowcaddence Road, Glasgow, G4 0BA, UK.

出版信息

Int Ophthalmol. 2024 Apr 14;44(1):175. doi: 10.1007/s10792-024-03122-9.

Abstract

AIM

This study aimed to assess the efficacy of hp-guar eye drops on tear film index and ocular surface dynamics under desiccating conditions using protection and relief treatment modalities.

METHODOLOGY

The 12 normal, non-dry eye participants were subjected to adverse environmental conditions using a Controlled Environment Chamber (CEC) where the relative humidity (RH) was 5% and the ambient temperature was 21 °C. The participants were screened for ocular symptoms, tear osmolarity, ocular surface temperature (OST), tear production using the Ocular Surface Disease Index questionnaire (OSDI), OcuSense TearLab Osmometer, FLIR System ThermaCAM P620, and Schirmer strips. Tear production was calculated by the Tear Function Index test (TFI).

RESULTS

The mean tear film osmolarity decreased significantly from 296 mOsm/L at 40% RH to 285 mOsm/L at 5% RH (p = 0.01). Conflicting responses were seen for osmolarity in protection and relief. Mean tear osmolarity was significantly higher in the protection method in comparison to the relief method (p = 0.005). The mean TFI increased from 557 at 40% to 854 at 5% (p = 0.02). A significant increase in TFI was observed in the relief method in comparison with both 40% (p = 0.001) and 5% (p = 0.04). In the relief method, the mean TFI score went up to 1139 when hp-guar was installed. A significant improvement in ocular comfort was experienced in both the protection (p = 0.041) and relief (p = 0.010) methods at 5% RH. The instillation of hp-guar drops in the relief method resulted in a significant reduction in OST. The mean OST dropped to 33.01 ºC, significantly lower than the recorded OST for both normal (p = 0.040) and dry (p = 0.014) environmental conditions.

CONCLUSION

Hp-guar drops significantly improve tear film parameters under a desiccating environment, however, tear film parameters respond differently to the management modalities. In the protection method, tear film osmolarity was protected against a dry environment, while in the relief mode, an improvement in tear production and a decrease in ocular surface temperature were seen. Hp-guar performance could be maximized for the management of exposure to adverse environments by using a treatment protocol that targets the most affected parameters in each group of patients. Using CEC has the potential to provide researchers with a readily available method to evaluate the efficiency of tear supplementation.

摘要

目的

本研究旨在评估 hp-guar 滴眼液在干燥环境下通过保护和缓解治疗方式对泪膜指数和眼表动力学的疗效。

方法

12 名正常非干眼参与者在受控环境室(CEC)中暴露于不利的环境条件下,相对湿度(RH)为 5%,环境温度为 21°C。使用眼表面疾病指数问卷(OSDI)、OcuSense TearLab 渗透压计、FLIR System ThermaCAM P620 和 Schirmer 条带评估参与者的眼部症状、泪液渗透压、眼表面温度(OST)和泪液分泌。泪液分泌通过泪膜功能指数测试(TFI)计算。

结果

泪膜渗透压平均值从 40% RH 时的 296mOsm/L 显著下降到 5% RH 时的 285mOsm/L(p=0.01)。保护和缓解措施中渗透压的反应不一致。与缓解方法相比,保护方法中的平均泪液渗透压显著更高(p=0.005)。与 40% RH 时的 557 相比,TFI 平均值在 5% RH 时增加到 854(p=0.02)。与 40% RH(p=0.001)和 5% RH(p=0.04)相比,缓解方法中 TFI 显著增加。在缓解方法中,当安装 hp-guar 滴眼剂时,平均 TFI 上升至 1139。在 5% RH 下,保护(p=0.041)和缓解(p=0.010)方法均显著改善眼部舒适度。在缓解方法中滴注 hp-guar 滴眼剂可显著降低 OST。平均 OST 降至 33.01°C,明显低于正常(p=0.040)和干燥(p=0.014)环境条件下记录的 OST。

结论

hp-guar 滴眼剂可显著改善干燥环境下的泪膜参数,但泪膜参数对管理方式的反应不同。在保护方法中,泪膜渗透压受到干燥环境的保护,而在缓解模式下,泪液分泌增加,眼表面温度降低。通过使用针对每组患者受影响最严重参数的治疗方案,hp-guar 的性能可在管理暴露于不利环境时得到最大程度的发挥。使用 CEC 有可能为研究人员提供一种现成的方法来评估泪液补充的效率。