Suppr超能文献

不同接骨板设计和螺钉排列对玩具贵宾犬桡骨螺钉取出后应力的有限元研究。

Finite element study on post-screw removal stress in toy poodle radius with different plate designs and screw arrangements.

机构信息

Laboratory of Veterinary Surgery, Joint Graduate School of Veterinary Medicine, Yamaguchi University, Japan.

Department of Surgery and Radiology, Faculty of Veterinary Medicine, Gadjah Mada University, Indonesia.

出版信息

Open Vet J. 2024 Mar;14(3):885-894. doi: 10.5455/OVJ.2024.v14.i3.16. Epub 2024 Mar 31.

Abstract

BACKGROUND

The study employs finite element analysis to investigate stress distribution in the radius of toy poodles after screw removal. The examination focuses on the biomechanical implications of varied screw hole configurations using 1.5 and 2.0-mm locking compression plates (LCPs) with notched head T-Plates.

AIM

To provide a noninvasive approach to analyzing the immediate consequences of screw removal from the radius bone in toy poodles. Specifically, it explores the impact of varied plate designs and screw arrangements on stress distribution within the forelimb bones.

METHODS

The study constructs a three-dimensional bone model of the toy poodle's forelimb based on computed tomography (CT) images. Simulations were designed to replicate jumping and landing from a 40 cm height, comparing stress distribution in the radius post-screw removal.

RESULTS

The analysis reveals significant variations in stress distribution patterns between the two LCPs. The radius implanted with the 2.0-mm LCP displays a uniform stress distribution, contrasting with the 1.5-mm plates. Localized stress concentration is observed around the screw holes, while trabecular bone regions near the screw holes exhibit lower stress levels.

CONCLUSION

The study highlights the plate designs and screw configurations that affect bone stress in toy poodle forelimbs post-screw removal. The findings provide valuable insights for veterinarians, aiding informed decisions in veterinary orthopedic practices.

摘要

背景

本研究采用有限元分析探讨玩具贵宾犬螺钉取出后桡骨的应力分布。该研究使用带缺口头 T 板的 1.5 和 2.0mm 锁定加压钢板(LCP),检查不同螺钉孔构型的生物力学意义。

目的

提供一种非侵入性方法来分析玩具贵宾犬桡骨螺钉取出后的即刻后果。具体来说,探讨了不同的钢板设计和螺钉排列对前肢骨骼内应力分布的影响。

方法

本研究基于 CT 图像构建了玩具贵宾犬前肢的三维骨骼模型。设计了模拟跳跃和从 40cm 高处着陆的实验,比较了螺钉取出后桡骨的应力分布。

结果

分析表明,两种 LCP 之间的应力分布模式有显著差异。植入 2.0mm LCP 的桡骨显示出均匀的应力分布,与 1.5mm 钢板形成对比。在螺钉孔周围观察到局部应力集中,而螺钉孔附近的小梁骨区域的应力水平较低。

结论

该研究强调了影响玩具贵宾犬前肢螺钉取出后骨骼应力的钢板设计和螺钉构型。研究结果为兽医提供了有价值的信息,有助于在兽医矫形实践中做出明智的决策。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/2fc9/11052620/aef125793ab3/OpenVetJ-14-885-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。