This study presents the development of a sandwich ELISA method for gluten detection in foods, using recombinant Fab antibody fragments against gliadin. The Fabs were chemically biotinylated and immobilized on streptavidin-coated plates as capture antibodies, while alkaline phosphatase-conjugated Fabs were used as detection antibodies. Four different gliadin-binding Fabs were tested and the Fab pair Fab8E-4 and Fab-C showed the best compatibility. An indirect sandwich immunoassay, using unmodified Fab8E-4 for capture and Fab-C as the detection antibody, achieved a detection limit of 26 ng/mL of gliadin, corresponding to 10 mg/kg of gluten in foods. No cross-reactivity was observed against 60 gluten-free species commonly used in the food industry. Analysis of 50 commercial products demonstrated consistent results compared to the standard method for gluten detection. The complete lack of cross-reactivity of the developed immunoassay with oat products potentially provides an advantage over other gluten detection systems.
本研究介绍了一种用于食品中麸质检测的夹心酶联免疫吸附测定(ELISA)方法的开发,该方法使用针对麦醇溶蛋白的重组Fab抗体片段。这些Fab片段经化学生物素化后作为捕获抗体固定在链霉亲和素包被的板上,而碱性磷酸酶偶联的Fab片段用作检测抗体。测试了四种不同的与麦醇溶蛋白结合的Fab片段,发现Fab8E-4和Fab-C这一对表现出最佳的兼容性。使用未修饰的Fab8E-4作为捕获抗体、Fab-C作为检测抗体的间接夹心免疫测定法,对麦醇溶蛋白的检测限为26 ng/mL,相当于食品中10 mg/kg的麸质。未观察到与食品工业中常用的60种无麸质品种有交叉反应。对50种商业产品的分析表明,与麸质检测的标准方法相比,结果一致。所开发的免疫测定法与燕麦产品完全没有交叉反应,这可能是其相对于其他麸质检测系统的一个优势。