Eriksson Margareta B E, Rosén Ingmar, Sjölund Bengt
Department of Clinical Neurophysiology University Hospital. S-221 85 LundSweden Department of Neurosurgery, University Hospital. S-221 85 LundSweden.
Pain. 1985 Jul;22(3):235-242. doi: 10.1016/0304-3959(85)90023-5.
Using the thermal sense as a model for nociception, the effects of conventional and acupuncture-like transcutaneous nerve stimulation (TNS) were tested on thresholds for warm and cold sensation in 8 healthy subjects. Photic stimulation did not change the thermically neutral zone (the warm-cold difference limen) from that seen under baseline conditions. However, the thermal difference limen usually increased with both types of TNS. The effect was ipsi- as well as contralateral, implying that a central inhibitory mechanism is activated by conventional and acupuncture-like TNS.