Suppr超能文献

手套拉伸和储存温度对芬太尼渗透的评估:对标准测试方法和个人防护装备建议的影响。

Assessment of glove stretch and storage temperature on fentanyl permeation: Implications for standard test methods and PPE recommendations.

作者信息

Fisher Edward M, Streeter Rebecca T, Hofacre Kent C, Greenawald Lee Ann, Yoon N Katherine, Soo Jhy-Charm, Keyes Patrick H

机构信息

National Personal Protective Technology Laboratory, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, Pittsburgh, Pennsylvania.

Battelle, Columbus, Ohio.

出版信息

J Occup Environ Hyg. 2024 Aug;21(8):529-538. doi: 10.1080/15459624.2024.2346294. Epub 2024 Jun 3.

Abstract

The National Institute for Occupational Safety and Health recommends the use of nitrile gloves with a minimum thickness of 5.0 ± 2.0 mil [0.127 ± 0.051 millimeters] in situations where it is suspected or known that fentanyl or other illicit drugs are present. However, there is limited data available on fentanyl permeation through gloves. Current test methods used to measure fentanyl permeation do not consider the effect of glove fit and flexion. Furthermore, first responders need to have PPE readily available in the field, and storage conditions may affect the protective performance of the gloves. The objective of this study was to evaluate the effects of glove stretch and storage temperatures on glove durability and barrier performance against fentanyl. Nine nitrile glove models previously shown to be resistant to fentanyl permeation were selected for this investigation. These nine models were stretched 25% in one linear direction, to consider glove fit and flexion, and tested against fentanyl hydrochloride permeation. Additionally, four of the nine glove models were stored at 48 °C, 22 °C, and -20 °C, and evaluated for tensile strength, ultimate elongation, and puncture resistance after up to 16 wk of storage and fentanyl permeation after up to 8 wk of storage. At least one sample for six of the nine tested models had maximum permeation over the test method fail threshold when stretched. The tested storage temperatures showed no effect on glove tensile strength, ultimate elongation, and puncture resistance. The findings of this study can be used to inform PPE recommendations, with consideration to storage practices and proper sizing for first responders with potential exposure to fentanyl and other illicit drugs. The results of this study can be used to assess the need for new standard test methods to evaluate the barrier performance of gloves and shelf-life determination with consideration to glove fit.

摘要

美国国家职业安全与健康研究所建议,在怀疑或已知存在芬太尼或其他非法药物的情况下,使用最小厚度为5.0±2.0密耳[0.127±0.051毫米]的丁腈手套。然而,关于芬太尼透过手套的渗透情况,现有数据有限。目前用于测量芬太尼渗透的测试方法未考虑手套贴合度和弯曲的影响。此外,急救人员需要在现场随时备有个人防护装备,而储存条件可能会影响手套的防护性能。本研究的目的是评估手套拉伸和储存温度对其耐用性以及对芬太尼的阻隔性能的影响。本调查选择了九种先前已证明能抵抗芬太尼渗透的丁腈手套型号。这九种型号在一个线性方向上拉伸25%,以考虑手套贴合度和弯曲情况,并测试其对盐酸芬太尼渗透的抵抗能力。此外,九种手套型号中的四种分别储存在48°C、22°C和-20°C下,在储存长达16周后评估其拉伸强度、极限伸长率和抗穿刺性,并在储存长达8周后评估其对芬太尼的渗透情况。九种测试型号中的六种,至少有一个样品在拉伸时的最大渗透率超过了测试方法的失败阈值。测试的储存温度对手套的拉伸强度、极限伸长率和抗穿刺性没有影响。本研究结果可用于为个人防护装备的建议提供参考,同时考虑储存方法以及为可能接触芬太尼和其他非法药物的急救人员选择合适尺寸的手套。本研究结果可用于评估是否需要新的标准测试方法来评估手套的阻隔性能以及考虑手套贴合度的保质期测定。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验