多中心 4F 系统构建的动静脉内瘘两年通畅率结果

Multi-Center Two-Year Patency Outcomes of Endovascular Arteriovenous Fistulas (endoAVF) Created with a 4 French System.

机构信息

Department of Medical Imaging and Interventional Radiology, Moffitt Cancer Center, Tampa, FL, USA.

Department of Interventional Radiology, Butler Health System, Butler, PA, USA.

出版信息

Cardiovasc Intervent Radiol. 2024 Aug;47(8):1045-1054. doi: 10.1007/s00270-024-03754-5. Epub 2024 Jun 5.

Abstract

PURPOSE

To assess multicenter two-year patency outcomes of endovascular arteriovenous fistulas (endoAVF) created with the WavelinQ device.

MATERIALS AND METHODS

Patients who had fistulas created at three centers from January 2018 to December 2020 were included in this retrospective study. In total, 112 patients underwent endoAVF creation [40 females, 72 males; mean age 60 years (range 18-88)]. Data collected included patient demographics, location of fistula creation, interventions performed, and brachial artery flows pre- and post-creation. Two-year cumulative patency, functional patency, and primary patency were assessed with Kaplan-Meier methodology. Factors affecting patency and maturation were examined using the Cox proportional hazards model.

RESULTS

Technical success defined as angiographically successful endoAVF creation was 97.3% (109/112). In 11 patients the fistula did not mature for dialysis use. For 98 patients (87%) with endoAVF maturation, 12- and 24-month cumulative patency was 94.3% and 91.7%. Functional patency (two-needle cannulation) at 12 and 24 months was 95.7% and 92.7%, respectively. Median maturation time is 95 days (IQR 51-231 days). Male gender and brachial vein coiling at the time of endoAVF creation were predictive of maturation. There were 34 censored events (four patients undergoing renal transplantation; 30 patients deceased). Number of reinterventions per patient year was 0.73 where 43 were maturation procedures and 101 were maintenance procedures. One Grade 3 complication occurred of arterial access puncture site pseudoaneurysm.

CONCLUSION

A high two-year functional and cumulative patency following endoAVF creation with the WavelinQ device was observed in this multicenter real-world experience Level of Evidence: 3 Level of Evidence III.

摘要

目的

评估使用 WavelinQ 装置进行的腔内动静脉瘘(endoAVF)的两年多中心通畅率结果。

材料和方法

本回顾性研究纳入了 2018 年 1 月至 2020 年 12 月在三个中心接受瘘管治疗的患者。共 112 例患者接受了 endoAVF 治疗[40 例女性,72 例男性;平均年龄 60 岁(范围 18-88 岁)]。收集的数据包括患者人口统计学特征、瘘管位置、手术操作以及造瘘前后肱动脉流量。使用 Kaplan-Meier 方法评估两年累计通畅率、功能性通畅率和原发性通畅率。使用 Cox 比例风险模型评估影响通畅率和成熟度的因素。

结果

技术成功率定义为血管造影成功的 endoAVF 造瘘术为 97.3%(109/112)。11 例患者的瘘管未成熟,无法用于透析。对于 98 例(87%)endoAVF 成熟的患者,12 个月和 24 个月的累计通畅率分别为 94.3%和 91.7%。功能性通畅率(双针穿刺)在 12 个月和 24 个月时分别为 95.7%和 92.7%。中位成熟时间为 95 天(IQR 51-231 天)。男性性别和造瘘时肱静脉卷曲是成熟的预测因素。有 34 例患者因 4 例接受肾移植;30 例患者死亡而被删失。每位患者每年的再干预次数为 0.73 次,其中 43 次为成熟术,101 次为维持术。仅发生 1 例 3 级并发症(动脉入路穿刺部位假性动脉瘤)。

结论

在这项多中心真实世界研究中,使用 WavelinQ 装置进行的 endoAVF 治疗两年后的功能性和累计通畅率较高。

证据等级

3 级

证据等级 III