Suppr超能文献

根管再治疗期间治疗变量对根尖碎屑挤出的影响:实验室研究的系统评价和荟萃分析

Effect of treatment variables on apical extrusion of debris during root canal retreatment: A systematic review and meta-analysis of laboratory studies.

作者信息

Uzunoğlu Özyürek Emel, Küçükkaya Eren Selen, Karahan Sevilay

机构信息

Department of Endodontics, Faculty of Dentistry, Hacettepe University, Ankara, Turkey.

出版信息

J Dent Res Dent Clin Dent Prospects. 2024 Winter;18(1):1-16. doi: 10.34172/joddd.40501. Epub 2024 Mar 29.

Abstract

BACKGROUND

This study aimed to systematically and comprehensively review the effect of various treatment variables on apically extruded debris (AED) during non-surgical root canal retreatment (NSRCRT).

METHODS

The study protocol is shared in the Open Science Framework database (https://osf.io/kjtdg/?view_only=17060180705745ec9dae9a01614f3880). An electronic search was conducted up to July 2022 to reveal related studies. Two reviewers critically assessed the studies for eligibility against inclusion and exclusion criteria and data extraction. Quantitative data synthesis was performed, and the risk of bias in the studies was also evaluated.

RESULTS

Forty-six studies were included in the systematic review and 14 in the meta-analysis. Conflicting or limited evidence was found for the effect of sealer type, obturation technique, and solvent use. The manual instrumentation increased the amount of AED compared to rotary instrumentation during the removal of filling materials (<0.001). There was no significant difference in the amount of AED between the use of rotary and reciprocating files during the removal of filling materials (=0.181).

CONCLUSION

Rotary instruments can be recommended instead of manual instruments during the removal of filling materials to control the amount of AED. Further studies with a low risk of bias are needed to clarify the effect of other treatment variables on AED during NSRCRT.

摘要

背景

本研究旨在系统全面地综述非手术根管再治疗(NSRCRT)期间各种治疗变量对根尖挤出碎屑(AED)的影响。

方法

研究方案在开放科学框架数据库(https://osf.io/kjtdg/?view_only=17060180705745ec9dae9a01614f3880)中共享。截至2022年7月进行了电子检索以揭示相关研究。两名评审员严格评估研究是否符合纳入和排除标准以及数据提取情况。进行了定量数据综合分析,并评估了研究中的偏倚风险。

结果

系统评价纳入46项研究,荟萃分析纳入14项研究。对于封闭剂类型、充填技术和溶剂使用的影响,发现了相互矛盾或有限的证据。在去除充填材料期间,与旋转器械相比,手动器械增加了AED的量(<0.001)。在去除充填材料期间,使用旋转锉和往复锉之间的AED量没有显著差异(=0.181)。

结论

在去除充填材料期间,可推荐使用旋转器械而非手动器械来控制AED的量。需要进行偏倚风险较低的进一步研究,以阐明NSRCRT期间其他治疗变量对AED的影响。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/da57/11179139/f11027426602/joddd-18-1-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验