Suppr超能文献

猫血液样本中,经卡那霉素处理的乙二胺四乙酸依赖性假性血小板减少症。

Kanamycin treated-ethylenediamine tetraacetic acid-dependent pseudothrombocytopenia in blood specimen of cats.

机构信息

Faculty of Veterinary Science, Prince of Songkla University, Songkhla, Thailand.

Hematology and Biochemistry Laboratory Unit, Veterinary Teaching Hospital, Faculty of Veterinary Science, Prince of Songkla University, Songkhla, Thailand.

出版信息

Open Vet J. 2024 May;14(5):1199-1205. doi: 10.5455/OVJ.2024.v14.i5.15. Epub 2024 May 31.

Abstract

BACKGROUND

Pseudothrombocytopenia is a commonly obtained false negative result when analyzing feline platelet (PLT) count by an automated machine. It is related to ethylenediamine tetra-acetic acid (EDTA), a widely utilized anticoagulant in blood collection tubes, resulting in EDTA-dependent pseudothrombocytopenia (EDTA-PTCP).

AIM

To investigate whether treated with kanamycin enhanced the quantity of PLT aggregations in feline blood specimens collected using EDTA-PTCP.

METHODS

Thirty-one blood samples were obtained using EDTA tubes. The complete blood count was analyzed using an automated Mindray BC-5000Vet. Both Manual cell counts and thin blood smears were performed to estimate the amount of red blood cell, white blood cell, and PLTs as well as to evaluate the severity scores of PLT clumping, respectively. Comparisons were made between those pre-treated and those treated with kanamycin in the EDTA tube.

RESULTS

There were significantly different mean PLT counts in the samples before and after they were treated with kanamycin, both on automated (156.6 ± 76.4 . 260.3 ± 115.5; < 0.001) and manual (168.5 ± 92.1 . 262.8 ± 119.6; < 0.001) readings, with a 95% confidence interval of 0.19 (0.022-0.365).

CONCLUSION

This study suggests that in clinical laboratory practice, kanamycin should be added to feline blood specimens with EDTA-PTCP.

摘要

背景

当使用自动化仪器分析猫的血小板(PLT)计数时,乙二胺四乙酸(EDTA)会导致假性血小板减少症,这是一种常见的假阴性结果。EDTA 依赖性假性血小板减少症(EDTA-PTCP)与 EDTA 广泛用于采血管抗凝有关。

目的

研究是否用卡那霉素处理 EDTA-PTCP 采集的猫血标本可以增强 PLT 聚集。

方法

用 EDTA 管采集 31 份血样。使用迈瑞 BC-5000Vet 全自动血液细胞分析仪进行全血细胞计数分析。分别进行手动细胞计数和薄血涂片,以估计红细胞、白细胞和 PLT 的数量,并评估 PLT 聚集的严重程度评分。比较 EDTA 管中未处理和用卡那霉素处理的样本。

结果

用卡那霉素处理前后的样本 PLT 计数均值在自动(156.6 ± 76.4. 260.3 ± 115.5;<0.001)和手动(168.5 ± 92.1. 262.8 ± 119.6;<0.001)读数上均有显著差异,95%置信区间为 0.19(0.022-0.365)。

结论

本研究表明,在临床实验室实践中,对于 EDTA-PTCP 的猫血标本,应添加卡那霉素。