Suppr超能文献

氟苯丙胺淀粉样蛋白 PET 采集时间:对百分位值的影响及解读。

Florbetaben amyloid PET acquisition time: Influence on Centiloids and interpretation.

机构信息

Department of Neurology and Neurological Sciences, Stanford University School of Medicine, Stanford, California, USA.

Department of Psychology, Stanford University, Stanford, California, USA.

出版信息

Alzheimers Dement. 2024 Aug;20(8):5299-5310. doi: 10.1002/alz.13893. Epub 2024 Jul 4.

Abstract

INTRODUCTION

Amyloid positron emission tomography (PET) acquisition timing impacts quantification.

METHODS

In florbetaben (FBB) PET scans of 245 adults with and without cognitive impairment, we investigated the impact of post-injection acquisition time on Centiloids (CLs) across five reference regions. CL equations for FBB were derived using standard methods, using FBB data collected between 90 and 110 min with paired Pittsburgh compound B data. Linear mixed models and t-tests evaluated the impact of acquisition time on CL increases.

RESULTS

CL values increased significantly over the scan using the whole cerebellum, cerebellar gray matter, and brainstem as reference regions, particularly in amyloid-positive individuals. In contrast, CLs based on white matter-containing reference regions decreased across the scan.

DISCUSSION

The quantification of CLs in FBB PET imaging is influenced by both the overall scan acquisition time and the choice of reference region. Standardized acquisition protocols or the application of acquisition time-specific CL equations should be implemented in clinical protocols.

HIGHLIGHTS

Acquisition timing affects florbetaben positron emission tomography (PET) scan quantification, especially in amyloid-positive participants. The impact of acquisition timing on quantification varies across common reference regions. Consistent acquisitions and/or appropriate post-injection adjustments are needed to ensure comparability of PET data.

摘要

简介

淀粉样蛋白正电子发射断层扫描(PET)的采集时间会影响定量分析。

方法

在 245 名认知障碍患者和认知正常者的氟比洛芬(FBB)PET 扫描中,我们研究了在五个参考区域中,注射后采集时间对 Centiloids(CL)的影响。使用标准方法,根据 90 到 110 分钟之间采集的 FBB 数据和配对的匹兹堡化合物 B 数据,为 FBB 推导了 CL 方程。线性混合模型和 t 检验评估了采集时间对 CL 增加的影响。

结果

使用整个小脑、小脑灰质和脑干作为参考区域,CL 值在整个扫描过程中显著增加,特别是在淀粉样蛋白阳性个体中。相比之下,基于包含白质的参考区域的 CL 则在整个扫描过程中下降。

讨论

FBB PET 成像中 CL 的定量受总扫描采集时间和参考区域选择的影响。在临床方案中应实施标准化采集协议或应用特定采集时间的 CL 方程。

要点

采集时间会影响氟比洛芬正电子发射断层扫描(PET)扫描的定量,尤其是在淀粉样蛋白阳性的参与者中。采集时间对定量的影响在常见的参考区域中有所不同。为了确保 PET 数据的可比性,需要进行一致的采集和/或适当的注射后调整。