穿戴式低强度连续超声波对延迟性肌肉酸痛期间肌肉生物力学特性的影响。

Effects of wearable low-intensity continuous ultrasound on muscle biomechanical properties during delayed onset muscle soreness.

机构信息

Department of Physical Therapy, Sunmoon University, Asan, Korea.

R&D Team, Refind Inc., Wonju, Korea.

出版信息

Technol Health Care. 2024;32(5):3253-3262. doi: 10.3233/THC-231947.

Abstract

BACKGROUND

Delayed onset muscle soreness (DOMS) is one of the most prevalent musculoskeletal symptoms in individuals engaged in strenuous exercise programs.

OBJECTIVE

This study investigated the effects of wearable low-intensity continuous ultrasound on muscle biomechanical properties during DOMS.

METHODS

Twenty volunteers were distributed into a wearable ultrasound stimulation group (WUG) (n= 10) and medical ultrasound stimulation group (MUG) (n= 10). All subjects performed wrist extensor muscle strength exercises to induce DOMS. At the site of pain, ultrasound of frequency 3 MHz was applied for 1 h or 5 min in each subject of the WUG or MUG, respectively. Before and after ultrasound stimulation, muscle biomechanical properties (tone, stiffness, elasticity, stress relaxation time, and creep) and body temperature were measured, and pain was evaluated.

RESULTS

A significant decrease was found in the tone, stiffness, stress relaxation time, and creep in both groups after ultrasound stimulation (all p< 0.05). A significant decrease in the pain and increases in temperature were observed in both groups (all p< 0.05). No significant differences were observed between the groups in most evaluations.

CONCLUSION

The stiffness and pain caused by DOMS were alleviated using a wearable ultrasound stimulator. Furthermore, the effects of the wearable ultrasound stimulator were like those of a medical ultrasound stimulator.

摘要

背景

延迟性肌肉酸痛(DOMS)是进行剧烈运动计划的个体中最常见的肌肉骨骼症状之一。

目的

本研究探讨了穿戴式低强度连续超声波对 DOMS 期间肌肉生物力学特性的影响。

方法

将 20 名志愿者分为穿戴式超声波刺激组(WUG)(n=10)和医用超声波刺激组(MUG)(n=10)。所有受试者均进行腕伸肌力量训练以引起 DOMS。在疼痛部位,WUG 或 MUG 中每个受试者分别接受频率为 3 MHz 的超声波治疗 1 小时或 5 分钟。在超声刺激前后,测量肌肉生物力学特性(张力、硬度、弹性、应力松弛时间和蠕变)和体温,并评估疼痛。

结果

两组在超声刺激后张力、硬度、应力松弛时间和蠕变均显著降低(均 p<0.05)。两组的疼痛均显著减轻,体温均显著升高(均 p<0.05)。大多数评估中,两组间无显著差异。

结论

穿戴式超声波刺激器可减轻 DOMS 引起的硬度和疼痛。此外,穿戴式超声波刺激器的效果类似于医用超声波刺激器。