Suppr超能文献

不同类型泡沫轴自我肌筋膜松解治疗的恢复效果。

Recovery effect of self-myofascial release treatment using different type of a foam rollers.

机构信息

Department of Theory of Sport, Józef Piłsudski University of Physical Education in Warsaw, Marymoncka 34 St., 00-968, Warsaw, Poland.

Department of Human Biology, Józef Piłsudski University of Physical Education in Warsaw, Marymoncka 34 St., 00-968, Warsaw, Poland.

出版信息

Sci Rep. 2024 Jul 9;14(1):15762. doi: 10.1038/s41598-024-66577-x.

Abstract

Among athletes, foam rolling is popular technique of myofascial release aimed to support recovery processes and counteract delayed onset muscle soreness. However, there is no consensus on the optimal parameters of the roller texture used in the procedure. The study aimed to determine whether using rollers with different textures and hardness (smooth/soft, grooved/mid, serrated/hard) in myofascial release affects post-exertional restitution rate and the level of perceived DOMS (Delayed Onset Muscle Soreness) after intense anaerobic exercise. The study involved 60 healthy and physically active men randomly divided into three experimental groups and one control group (passive rest)-each consisting of 15 individuals: STH-rolling with a smooth roller; G-rolling with a grooved roller; TP-rolling with a serrated roller; Pass-passive rest group. After performing a exercise test (one-minute high-intensity squat), blood lactate (LA), creatine kinase (CK) and pain perception (VAS Scale) were monitored. The analysis of the average LA concentration in the blood 30 min post-exercise showed a statistical difference for all rolling groups compared to the passive rest group: STH (p < 0.001), G (p < 0.001), TP (p = 0.035). No statistically significant differences were found between the CK measurement results in individual assessments. Statistically significant differences in VAS values were observed between G (p = 0.013) and TP (p = 0.006) groups and the Pass group at 48 h, as well as between STH (p = 0.003); G (p = 0.001); TP (p < 0.001) groups and the Pass group at 72 h. Based on statistical data, a strong influence (η = 0.578) of time on the quadriceps VAS variable was noted. The research results confirm the effectiveness of rolling in supporting immediate and prolonged recovery. The conducted studies indicate a significantly better pace of post-exertional recovery after a rolling procedure lasting at least 120 s. The texture and hardness of the tool used did not matter with such a duration of the treatment.

摘要

在运动员中,泡沫轴滚动是一种流行的肌筋膜松解技术,旨在支持恢复过程并对抗延迟性肌肉酸痛。然而,对于在该过程中使用的滚轮纹理的最佳参数,目前尚未达成共识。本研究旨在确定在肌筋膜松解中使用不同纹理和硬度(光滑/软、有槽/中、锯齿/硬)的滚轮是否会影响剧烈无氧运动后的恢复速度和迟发性肌肉酸痛(DOMS)的感知程度。该研究涉及 60 名健康且活跃的男性,他们被随机分为三个实验组和一个对照组(被动休息),每组 15 人:STH-使用光滑滚轮滚动;G-使用有槽滚轮滚动;TP-使用锯齿滚轮滚动;Pass-被动休息组。在进行运动测试(一分钟高强度深蹲)后,监测血液中乳酸(LA)、肌酸激酶(CK)和疼痛感知(VAS 量表)。对运动后 30 分钟血液中平均 LA 浓度的分析表明,与被动休息组相比,所有滚动组均存在统计学差异:STH(p<0.001)、G(p<0.001)、TP(p=0.035)。在各个评估中,CK 测量结果之间未发现统计学差异。在 VAS 值方面,G 组(p=0.013)和 TP 组(p=0.006)与 Pass 组在 48 小时时以及 STH 组(p=0.003)、G 组(p=0.001)、TP 组(p<0.001)与 Pass 组在 72 小时时存在统计学差异。基于统计数据,注意到时间对股四头肌 VAS 变量的强烈影响(η=0.578)。研究结果证实了滚动在支持即时和长期恢复方面的有效性。进行的研究表明,在持续至少 120 秒的滚动程序后,恢复速度明显加快。在这种治疗持续时间内,使用的工具的纹理和硬度并不重要。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3527/11233653/898370771103/41598_2024_66577_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验