Suppr超能文献

声学阴影掩盖的重度人工二尖瓣反流:频谱多普勒在人工瓣膜评估中的重要性

Severe Prosthetic Mitral Valve Regurgitation Hidden by Acoustic Shadowing: The Importance of Spectral Doppler in Prosthetic Valve Assessment.

作者信息

Carnazzo Maria Chiara, Al Ibraheem Boshra M, Calvin Andrew D

机构信息

Post-graduate School of Emergency Medicine, Faculty of Medicine and Surgery, University of Modena and Reggio Emilia, Modena, Italy.

Department of Vascular Surgery, Mayo Clinic Health System, Eau Claire, Wisconsin.

出版信息

CASE (Phila). 2024 May 7;8(6):359-363. doi: 10.1016/j.case.2024.03.004. eCollection 2024 Jun.

Abstract

• Acoustic shadowing limits Doppler evaluation in PHVs, potentially masking MR. • Spectral Doppler is an important tool to detect prosthetic MR. • TEE can supplement TTE, partially avoiding acoustic shadowing and reverberations.

摘要

• 声影限制了经皮心室辅助装置(PHV)中的多普勒评估,可能掩盖二尖瓣反流(MR)。

• 频谱多普勒是检测人工瓣膜二尖瓣反流的重要工具。

• 经食管超声心动图(TEE)可补充经胸超声心动图(TTE),部分避免声影和混响。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/813a/11227996/1bb9282d9fea/ga1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验