Suppr超能文献

容积调强弧形放疗中不同头倾角度用于海马回避全脑放疗的评估

Assessment of different head tilt angles in volumetric modulated arc therapy for hippocampus-avoidance whole-brain radiotherapy.

作者信息

Yuan Cuiyun, Xu Sisi, Li Yang, Quan Enzhuo, Chen Dongjie, Liang Jun, Liu Chenbin

机构信息

National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, China.

出版信息

Front Oncol. 2024 Jun 27;14:1415471. doi: 10.3389/fonc.2024.1415471. eCollection 2024.

Abstract

PURPOSE

In the field of radiation therapy for brain metastases, whole-brain hippocampus-avoidance treatment is commonly employed. this study aims to examine the impact of different head tilt angles on the dose distribution in the whole-brain target area and organs at risk. It also aims to determine the head tilt angle to achieve optimal radiation therapy outcomes.

METHODS

CT images were collected from 8 brain metastases patients at 5 different groups of head tilt angle. The treatment plans were designed using the volumetric modulated arc therapy (VMAT) technique. The 5 groups of tilt angle were as follows: [0°,10°), [10°,20°), [20°,30°), [30°,40°), and [40°,45°]. The analysis involved assessing parameters such as the uniformity index, conformity index, average dose delivered to the target, dose coverage of the target, hot spots within the target area, maximum dose, and average dose received by organs at risk. Additionally, the study evaluated the correlation between hippocampal dose and other factors, and established linear regression models.

RESULTS

Significant differences in dosimetric results were observed between the [40°,45°] and [0°,10°) head tilt angles. The [40°,45°] angle showed significant differences compared to the [0°,10°) angle in the average dose in the target area (31.49 ± 0.29 Gy vs. 31.99 ± 0.29 Gy, p=0.016), dose uniformity (1.20 ± 0.03 vs. 1.24 ± 0.03, p=0.016), hotspots in the target area (33.64 ± 0.35 Gy vs. 34.42 ± 0.49 Gy, p=0.016), maximum hippocampal dose (10.73 ± 0.36 Gy vs. 11.66 ± 0.59 Gy, p=0.008), maximum dose in the lens (2.82 ± 1.10 Gy vs. 4.99 ± 0.16 Gy, p=0.016), and average dose in the lens (1.93 ± 0.29 Gy vs. 4.22 ± 0.26 Gy, p=0.008). There is a moderate correlation between the maximum dose in the hippocampi and the PTV length (r=0.49, p=0.001). Likewise, the mean dose in the hippocampi is significantly correlated with the hippocampi length (r=0.34, p=0.04).

CONCLUSION

The VMAT plan with a head tilt angle of [40°,45°] met all dose constraints and demonstrated improved uniformity of the target area while reducing the dose to organs at risk. Furthermore, the linear regression models suggest that increasing the head tilt angle within the current range of [0°,45°] is likely to lead to a decrease in the average hippocampal dose.

摘要

目的

在脑转移瘤放射治疗领域,全脑海马回避治疗被广泛应用。本研究旨在探讨不同头部倾斜角度对全脑靶区及危及器官剂量分布的影响,并确定能实现最佳放疗效果的头部倾斜角度。

方法

收集8例脑转移瘤患者在5组不同头部倾斜角度下的CT图像。采用容积调强弧形放疗(VMAT)技术设计治疗计划。5组倾斜角度分别为:[0°,10°)、[10°,20°)、[20°,30°)、[30°,40°)和[40°,45°]。分析涉及评估参数,如均匀性指数、适形指数、靶区平均剂量、靶区剂量覆盖、靶区内热点、最大剂量以及危及器官接受的平均剂量。此外,该研究评估了海马剂量与其他因素之间的相关性,并建立了线性回归模型。

结果

在[40°,45°]和[0°,10°)头部倾斜角度之间观察到剂量学结果存在显著差异。与[0°,10°)角度相比,[40°,45°]角度在靶区平均剂量(31.49±0.29 Gy对31.99±0.29 Gy,p = 0.016)、剂量均匀性(1.20±0.03对1.24±0.03,p = 0.016)、靶区内热点(33.64±0.35 Gy对34.42±0.49 Gy,p = 0.016)、最大海马剂量(10.73±0.36 Gy对11.66±0.59 Gy,p = 0.008)、晶状体最大剂量(2.82±1.10 Gy对4.99±0.16 Gy,p = 0.016)以及晶状体平均剂量(1.93±0.29 Gy对4.22±0.26 Gy,p = 0.008)方面均显示出显著差异。海马体最大剂量与PTV长度之间存在中度相关性(r = 0.49,p = 0.001)。同样,海马体平均剂量与海马体长显著相关(r = 0.34,p = 0.04)。

结论

头部倾斜角度为[40°,45°]的VMAT计划满足了所有剂量限制,在降低危及器官剂量的同时,靶区均匀性得到改善。此外,线性回归模型表明,在当前[0°,45°]范围内增加头部倾斜角度可能会导致海马体平均剂量降低。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/deb7/11236617/07cf3a112f35/fonc-14-1415471-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验