Abstract

The purpose of this work was to evaluate using Varian HyperArc as a planning and treatment solution for whole brain radiotherapy (WBRT) with hippocampal sparing following Radiation Therapy Oncology Group (RTOG) 0933 dosimetric criteria. Ten patients previously treated for intracranial lesions were retrospectively planned for WBRT with hippocampal sparing using HyperArc and a 2-arc coplanar VMAT technique. The whole brain and hippocampus were delineated on fused MRI and CT datasets. The planning target volume (PTV), defined as the whole brain excluding the hippocampal avoidance region, was prescribed 30 Gy in 10 fractions. Plans were evaluated using dosimetric parameters which included the volume of 105% of the prescription dose (V105%) and the maximum dose to the PTV, and the minimum dose to the hippocampus. The planning time, delivery time, and delivery quality assurance (QA) results were also evaluated. Statistical significance was performed between the HyperArc and coplanar VMAT metrics using the Wilcoxon signed-rank test with a significance level of 0.05. All plans met RTOG 0933 dosimetric criteria. HyperArc plans demonstrated significant improvements in PTV dosimetric quality which included a reduced V105% of 6 ± 7% and decreased maximum dose of 1.3 ± 0.3 Gy, compared to coplanar VMAT. Significant OAR sparing was also found for HyperArc plans that included a decreased minimum dose to the hippocampus of 0.3 ± 0.3 Gy. Coplanar VMAT plans resulted in significantly shorter planning and delivery times, compared to HyperArc, by 2.4 minutes and 1.5 minutes, respectively. No significant difference was found between the delivery QA results. This study demonstrated using Varian HyperArc as a planning and treatment solution for WBRT with hippocampal sparing following RTOG 0933 dosimetric criteria. The primary advantages of WBRT with hippocampal sparing using HyperArc, compared to coplanar VMAT, are the gains in OAR sparing and reduced high dose volumes to the PTV.

摘要

这项工作的目的是评估使用瓦里安 HyperArc 作为放射治疗肿瘤学组 (RTOG) 0933 剂量学标准下全脑放疗 (WBRT) 并进行海马保护的计划和治疗解决方案。回顾性地为 10 名先前接受颅内病变治疗的患者计划 WBRT 并进行海马保护,使用 HyperArc 和 2 个共面 VMAT 技术。在融合的 MRI 和 CT 数据集上对整个大脑和海马体进行了描绘。计划靶区 (PTV) 定义为整个大脑,不包括海马体回避区,处方剂量为 30 Gy,分为 10 个部分。使用包括处方剂量的 105% (V105%) 和 PTV 的最大剂量以及海马体的最小剂量在内的剂量学参数评估计划。还评估了计划时间、交付时间和交付质量保证 (QA) 结果。使用 Wilcoxon 符号秩检验对 HyperArc 和共面 VMAT 指标进行统计学意义检验,显著性水平为 0.05。所有计划均符合 RTOG 0933 剂量学标准。与共面 VMAT 相比,HyperArc 计划在 PTV 剂量学质量方面显示出显著改善,包括 V105%降低了 6%±7%,最大剂量降低了 1.3%±0.3Gy。还发现 HyperArc 计划对 OAR 的保护也显著减少,包括海马体最小剂量降低了 0.3%±0.3Gy。与 HyperArc 相比,共面 VMAT 计划的计划和交付时间分别缩短了 2.4 分钟和 1.5 分钟。在交付 QA 结果方面没有发现显著差异。这项研究表明,使用瓦里安 HyperArc 作为 RTOG 0933 剂量学标准下全脑放疗 (WBRT) 并进行海马保护的计划和治疗解决方案。与共面 VMAT 相比,使用 HyperArc 进行 WBRT 并进行海马保护的主要优势是 OAR 保护的增加和 PTV 高剂量体积的减少。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验