Suppr超能文献

非骨水泥型罗伯特·马西斯压配髋臼杯的中期临床结果

Mid-term clinical outcomes of the uncemented Robert Mathys pressfit cup.

作者信息

Ramsodit Kishan Ritek, Sierevelt Inger N, Janssen Esther R C, Kaarsemaker Sjoerd, Haverkamp Daniël

机构信息

Department of Orthopedic Surgery, Xpert Clinics Amsterdam, Amsterdam 1101EA, North-Holland, Netherlands.

Department of Orthopedic, Spaarne Gasthuis Academy, Hoofddorp 2134 TM, Netherlands.

出版信息

World J Clin Cases. 2024 Jul 6;12(19):3684-3691. doi: 10.12998/wjcc.v12.i19.3684.

Abstract

BACKGROUND

The use of uncemented cups during total hip arthroplasty (THA) has gained popularity in recent years. The Robert Mathys (RM) pressfit cup, an uncemented monoblock implant is expected to preserve bone density due to its composition and external surface, while reducing backside wear with its monoblock construction. These factors should lead to a high survival rate of the implant.

AIM

To evaluate the mid-term survival and functional outcome of the RM Pressfit cup in a large study population.

METHODS

Between 2011 and 2020, we included 1324 patients receiving a primary THA using the RM pressfit cup. Final clinical follow-up was performed at 2 years postoperatively with the Dutch arthroplasty register used to assess implant status thereafter. Revision for acetabular failure and reason for revision were reported to evaluate implant survival, while the hip disability and osteoarthritis outcome score (HOOS) scores were used to assess functional outcome.

RESULTS

The mean age at surgery was 64.9 years. The mean follow-up was 4.6 years. Of the 1324 THAs performed, 13 needed cup revisions within 5 years after index THA: 5 due to aseptic loosening, 6 due to infection, 2 due to dislocation and 2 due to other causes. This resulted in a 5-year cup survival of 98.8% (95%CI: 98.1-99.5). Nine of the cup revisions occurred within the first year after index THA. HOOS scores increased significantly in all domains during the first year and levelled out during the second year.

CONCLUSION

In the present study, the RM pressfit cup demonstrated excellent clinical outcomes at mid-term follow-up; however, future studies are needed to assess the long-term outcomes of this acetabular implant.

摘要

背景

近年来,全髋关节置换术(THA)中使用非骨水泥杯已越来越普遍。罗伯特·马西斯(RM)压配杯是一种非骨水泥整体植入物,由于其成分和外表面,预计可保留骨密度,同时其整体结构可减少后侧磨损。这些因素应能使植入物具有较高的生存率。

目的

在一个大型研究人群中评估RM压配杯的中期生存率和功能结果。

方法

2011年至2020年期间,我们纳入了1324例使用RM压配杯进行初次THA的患者。术后2年进行最终临床随访,此后使用荷兰关节置换登记册评估植入物状态。报告髋臼失败翻修情况及翻修原因以评估植入物生存率,同时使用髋关节残疾和骨关节炎结果评分(HOOS)来评估功能结果。

结果

手术时的平均年龄为64.9岁。平均随访时间为4.6年。在1324例THA手术中,有13例在初次THA后5年内需要进行杯状假体翻修:5例因无菌性松动,6例因感染,2例因脱位,2例因其他原因。这导致杯状假体5年生存率为98.8%(95%CI:98.1 - 99.5)。9例杯状假体翻修发生在初次THA后的第一年内。HOOS评分在第一年所有领域均显著增加,并在第二年趋于平稳。

结论

在本研究中,RM压配杯在中期随访中显示出优异的临床结果;然而,需要进一步的研究来评估这种髋臼植入物的长期结果。