Suppr超能文献

使用术中像差仪、数字图像跟踪和飞秒激光植入三焦点散光人工晶状体后的效果

Outcomes After Implantation of a Trifocal Toric Intraocular Lens Using Intraoperative Aberrometry, Digital Image Tracking, and Femtosecond Laser.

作者信息

Melendez Robert F, Nguyen Thao Huong, Solis Angelica Isabella, Ortiz Danielle, Moezzi Cody, Hall Brad

机构信息

Juliette Eye Institute, Albuquerque, NM, USA.

University of New Mexico School of Medicine, Department of Ophthalmology, Albuquerque, NM, USA.

出版信息

Clin Ophthalmol. 2024 Jul 11;18:2033-2039. doi: 10.2147/OPTH.S460060. eCollection 2024.

Abstract

PURPOSE

To evaluate the refractive and visual acuity outcomes when using trifocal toric intraocular lenses (IOLs), femtosecond laser assisted cataract surgery (FLACS), swept-source optical coherence tomography (SS-OCT) biometry, digital image tracking (DT) and intraoperative aberrometry (IA).

METHODS

This prospective, single-arm, observational study of refractive and visual outcomes included 40 eyes of 34 subjects. Preoperative biometry was performed with the Argos, FLACS and digital marking with LenSx, and IA and DT with ORA. Eyes were implanted with the Clareon PanOptix toric IOL. Study outcome measures included absolute prediction error, residual refractive astigmatism, and monocular uncorrected and distance corrected visual acuity at distance (UDVA, CDVA), intermediate (UIVA, DCIVA; 60cm), and near (UNVA, DCNVA; 40cm).

RESULTS

Mean absolute prediction error (spherical equivalent) was 0.43 ± 0.36 D, and the percentage of eyes with absolute prediction error ≤ 0.5 D was 72.5% (29/40 eyes). Mean residual astigmatism was 0.36 ± 0.65 D, and the percentage of eyes with residual astigmatism ≤ 0.5 D was 80% (32/40 eyes). Monocular UDVA, UIVA, and UNVA was 20/25 or better in 75%, 64%, and 87% of eyes respectively. Monocular CDVA, DCIVA, and DCNVA was 20/25 or better in 95%, 64%, and 87% of eyes respectively.

CONCLUSION

The results of this study suggest that trifocal toric implantation with SS-OCT, FLACS, DT, and IA can provide excellent refractive and visual outcomes.

摘要

目的

评估使用三焦点散光人工晶状体(IOL)、飞秒激光辅助白内障手术(FLACS)、扫频光学相干断层扫描(SS-OCT)生物测量、数字图像跟踪(DT)和术中像差测量(IA)时的屈光和视力结果。

方法

这项关于屈光和视力结果的前瞻性、单臂观察性研究纳入了34名受试者的40只眼。术前使用Argos进行生物测量,使用LenSx进行FLACS和数字标记,使用ORA进行IA和DT。眼睛植入了Clareon PanOptix散光IOL。研究结果指标包括绝对预测误差、残余屈光散光以及单眼未矫正和距离矫正的远视力(UDVA、CDVA)、中视力(UIVA、DCIVA;60厘米)和近视力(UNVA、DCNVA;40厘米)。

结果

平均绝对预测误差(等效球镜)为0.43±0.36 D,绝对预测误差≤0.5 D的眼的百分比为72.5%(29/40只眼)。平均残余散光为0.36±0.65 D,残余散光≤0.5 D的眼的百分比为80%(32/40只眼)。单眼UDVA、UIVA和UNVA分别在75%、64%和87%的眼中达到20/25或更好。单眼CDVA、DCIVA和DCNVA分别在95%、64%和87%的眼中达到20/25或更好。

结论

本研究结果表明,采用SS-OCT、FLACS、DT和IA进行三焦点散光人工晶状体植入可提供优异的屈光和视力结果。