Suppr超能文献

不同复合材料在使用通用粘结剂粘结的II类洞中的临床性能。

Clinical performance of different composite materials in class II cavities bonded with universal adhesives.

作者信息

Özden Gülsüm, Karadas Muhammet

机构信息

Department of Restorative Dentistry, Faculty of Dentistry, Recep Tayyip Erdogan University, Rize, Turkey.

出版信息

J Esthet Restor Dent. 2025 Feb;37(2):314-325. doi: 10.1111/jerd.13285. Epub 2024 Jul 25.

Abstract

OBJECTIVE

To assess the clinical performance of two composite materials with two universal adhesives and a two-step self-etch adhesive on class II restorations for 18 months.

MATERIALS AND METHODS

Two hundred and fifty-two class II cavities were bonded with G-Premio Bond, Single Bond Universal, and Clearfil SE Bond 2. A nanohybrid composite (Filtek Z550 Universal) or a microhybrid composite (G-aenial Posterior) was used to fill the bonded cavities. World Dental Federation criteria were used to evaluate the restorations at 1 week, 6, and 18 months. Statistical analysis was performed using Friedman and Fisher's exact tests (α = 0.05).

RESULTS

Retention loss and fracture were not observed in any restorations during the 18 months. The adhesives used showed no significant differences for all criteria examined (p > 0.05) regardless of composite material. After an 18-month follow-up, seven G-aenial Posterior and three Filtek Z550 Universal restorations presented slight marginal discrepancies, with no significant differences (p = 0.246). At 1 week, Filtek Z550 Universal (9.5%) led to significantly higher postoperative sensitivity compared with G-aenial Posterior (0.8%) (p = 0.001).

CONCLUSIONS

Universal adhesives showed similar clinical performance to Clearfil SE Bond 2. The restorations with Filtek Z550 Universal had a relatively higher risk of postoperative sensitivity.

CLINICAL SIGNIFICANCE

Universal adhesives were clinically successful for 18 months. At 1 week, the type of composite material used significantly affected the occurrence of postoperative sensitivity.

摘要

目的

评估两种复合材料与两种通用型粘结剂以及一种两步法自酸蚀粘结剂用于Ⅱ类洞修复体18个月的临床性能。

材料与方法

252个Ⅱ类洞分别用G-Premio Bond、Single Bond Universal和Clearfil SE Bond 2进行粘结。采用纳米混合复合材料(Filtek Z550 Universal)或微混合复合材料(G-aenial Posterior)充填粘结后的窝洞。按照世界牙科联盟标准在1周、6个月和18个月时对修复体进行评估。采用Friedman检验和Fisher精确检验进行统计学分析(α = 0.05)。

结果

在18个月期间,所有修复体均未观察到固位丧失和折断。无论使用何种复合材料,所使用的粘结剂在所有检查标准方面均无显著差异(p > 0.05)。18个月随访后,7个G-aenial Posterior修复体和3个Filtek Z550 Universal修复体出现轻微边缘差异,无显著差异(p = 0.246)。在1周时,Filtek Z550 Universal(9.5%)导致的术后敏感率显著高于G-aenial Posterior(0.8%)(p = 0.001)。

结论

通用型粘结剂的临床性能与Clearfil SE Bond 2相似。Filtek Z550 Universal修复体术后敏感风险相对较高。

临床意义

通用型粘结剂在临床上成功应用了18个月。在1周时,所使用的复合材料类型显著影响术后敏感的发生。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/b4c5/11927801/8bcc58da2dd6/JERD-37-314-g002.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验