Elbarbary Nancy, Alguwaihes Abdullah, Zarif Hawazen, Hassanein Mohamed, Deeb Asma, Petrovski Goran, Al Dahash Raed, Alamoudi Reem, Hussain Sufyan, Ibrahim Mahmoud, Shaikh Shehla, Zainudin Sueziani Binte, Chaar Wael, van den Heuvel Tim, Al-Sofiani Mohammed E
Diabetes and Endocrinology Unit, Department of Pediatrics, Faculty of Medicine, Ain Shams University, Cairo, Egypt.
Division of Endocrinology, Department of Internal Medicine, College of Medicine, King Saud University, Riyadh, Saudi Arabia.
Diabetes Technol Ther. 2025 Jan;27(1):72-85. doi: 10.1089/dia.2024.0200. Epub 2024 Aug 22.
This article offers a systematic literature review (SLR) on the use of the MiniMed 780G automated insulin delivery system (MM780G) in people with type 1 diabetes (PwT1D) during Ramadan intermittent fasting. It also presents consensus recommendations on the use of MM780G during the Ramadan period. The SLR was performed following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses methodology. The recommendations resulted from a consensus-forming process involving a panel of experts. The process considered evidence found in the SLR as well as the expert opinions. In total, six studies were included in the SLR. The evidence and expert opinions led to recommendations related to (a) pre-Ramadan counseling of MM780G users who plan to fast; (b) suggested MM780G settings, meal announcement strategy, and safety aspects during Ramadan (including a contingency plan); and (c) post-Ramadan transition into and out of Eid-al-Fitr festivities. The SLR findings showed that the MM780G maintains glycemic control at target in PwT1D during Ramadan (meeting continuous glucose monitoring-based clinical targets proposed by the International Consensus on Time-in-Range) while ensuring low rates of hypoglycemia and diabetic ketoacidosis. Automated insulin delivery also helps PwT1D fast more days of Ramadan compared with users of other less advanced modalities of treatment. Pre-Ramadan guidance on specific aspects of the MM780G along with the International Diabetes Federation and Diabetes and Ramadan International Alliance counseling guidelines is recommended. There is still a challenge with post-Iftar hyperglycemia, which could potentially be mitigated by following the recommendations outlined in this article.
本文对1型糖尿病患者(PwT1D)在斋月间歇性禁食期间使用美敦力780G自动胰岛素输送系统(MM780G)进行了系统的文献综述(SLR)。它还提出了斋月期间使用MM780G的共识性建议。该SLR是按照系统评价与Meta分析的首选报告项目方法进行的。这些建议来自一个专家小组的共识形成过程。该过程考虑了SLR中发现的证据以及专家意见。SLR总共纳入了六项研究。证据和专家意见得出了与以下方面相关的建议:(a)对计划禁食的MM780G使用者进行斋月前咨询;(b)建议的斋月期间MM780G设置、进餐通知策略和安全方面(包括应急计划);以及(c)斋月后进入和离开开斋节庆祝活动的过渡。SLR结果表明,MM780G在斋月期间能使PwT1D的血糖维持在目标范围内(符合国际血糖波动时间共识提出的基于持续葡萄糖监测的临床目标),同时确保低血糖和糖尿病酮症酸中毒的发生率较低。与其他较不先进的治疗方式的使用者相比,自动胰岛素输送还能帮助PwT1D在斋月期间多禁食几天。建议结合国际糖尿病联合会和糖尿病与斋月国际联盟的咨询指南,对MM780G的具体方面进行斋月前指导。斋月晚餐后高血糖仍然是一个挑战,遵循本文概述的建议可能会缓解这一问题。