Neuroradiology Department, ASST Santi Paolo e Carlo, 20142 Milan, Italy.
Radiology Unit, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, P.le Spedali Civili 1, 25123 Brescia, Italy.
Tomography. 2024 Jun 28;10(7):1014-1023. doi: 10.3390/tomography10070075.
This study evaluates the repeatability and reproducibility of fat-fraction percentage (FF%) in whole-body magnetic resonance imaging (WB-MRI) of prostate cancer patients with bone metastatic hormone naive disease.
Patients were selected from the database of a prospective phase-II trial. The treatment response was assessed using the METastasis Reporting and Data System for Prostate (MET-RADS-P). Two operators identified a Small Active Lesion (SAL, <10 mm) and a Large Active Lesion (LAL, ≥10 mm) per patient, performing manual segmentation of lesion volume and the largest cross-sectional area. Measurements were repeated by one operator after two weeks. Intra- and inter-reader agreements were assessed via Interclass Correlation Coefficient (ICC) on first-order radiomics features.
Intra-reader ICC showed high repeatability for both SAL and LAL in a single slice (SS) and volumetric (VS) measurements with values ranging from 0.897 to 0.971. Inter-reader ICC ranged from 0.641 to 0.883, indicating moderate to good reproducibility. Spearman's rho analysis confirmed a strong correlation between SS and VS measurements for SAL (0.817) and a moderate correlation for LAL (0.649). Both intra- and inter-rater agreement exceeded 0.75 for multiple first-order features across lesion sizes.
This study suggests that FF% measurements are reproducible, particularly for larger lesions in both SS and VS assessments.
本研究评估了骨转移激素初治前列腺癌患者全身磁共振成像(WB-MRI)中脂肪分数(FF%)的重复性和可再现性。
从一项前瞻性 II 期试验的数据库中选择患者。使用前列腺转移报告和数据系统(MET-RADS-P)评估治疗反应。两名操作人员为每位患者识别一个小活动病变(SAL,<10mm)和一个大活动病变(LAL,≥10mm),手动分割病变体积和最大横截面积。一名操作人员在两周后重复测量。通过一阶放射组学特征的组内相关系数(ICC)评估内-和间-读者的一致性。
单层面(SS)和容积(VS)测量的 SAL 和 LAL 的内-读者 ICC 显示出高度的重复性,范围从 0.897 到 0.971。间-读者 ICC 范围从 0.641 到 0.883,表明具有中度到良好的可再现性。Spearman 秩相关分析证实了 SAL 在 SS 和 VS 测量之间具有很强的相关性(0.817),而 LAL 具有中度相关性(0.649)。在 SS 和 VS 评估中,多个一阶特征的内-和间-读者一致性均超过 0.75。
本研究表明,FF%测量具有可再现性,特别是在 SS 和 VS 评估中较大的病变。