Suppr超能文献

扫描体加或不加三维打印扫描辅助物对全牙弓数字扫描准确性的影响。

Influence of splinting scan bodies or incorporating three-dimensionally printed scan aids on the trueness of complete arch digital scans.

机构信息

Research Assistant, Department of Prosthetic Dentistry, Faculty of Dentistry, Near East University, Nicosia, North Cyprus.

Associate Professor, Department of Prosthetic Dentistry, Faculty of Dentistry, Near East University, Nicosia, North Cyprus.

出版信息

J Prosthet Dent. 2024 Oct;132(4):828.e1-828.e12. doi: 10.1016/j.prosdent.2024.07.001. Epub 2024 Jul 27.

Abstract

STATEMENT OF PROBLEM

Studies are sparse on how splinting scan bodies or incorporating 3-dimensionally (3D) printed scan aids influence the trueness of complete arch digital scans.

PURPOSE

The purpose of this in vitro study was to compare the trueness of multisite implant recordings obtained using 6 different methods on an edentulous mandible.

MATERIAL AND METHODS

A definitive cast of an edentulous mandible with 4 multi-unit analogs placed at different angles and interanalog distances was extraorally scanned, and the resulting data were saved as a reference file. To obtain experimental files, 6 distinct methods were used: conventional impression with splinted open-tray impression copings (IC), intraoral scanning (IOS) without splinting scan bodies or using any scan aids (SB), IOS with pattern resin-splinted scan bodies (PR), IOS with composite resin-splinted scan bodies (CR), IOS with 3D printed custom scan bodies (CSB), and IOS with 3D printed auxiliary apparatus (AA). The experimental files were aligned to the reference file in a metrology software program. The 3D comparison algorithm was run to quantify the root mean square estimate error (RMS). Scan bodies in the files were converted to hollow virtual cylinders, and the Cartesian coordinates of the lines passing through the centers of these cylinders were recorded to analyze angular (AD) and linear distortion (LD). LD was further analyzed along the x (∆X), y (∆Y), and z axes (∆Z). One-way ANOVAs with the Tukey HSD test were used for statistical analysis (α=.05).

RESULTS

AD at all sites, LD at all sites, and the RMS error showed significant differences (P<.05). The IC group showed the lowest AD values across all sites, followed by the AA, CSB, PR, CR, and SB groups. The SB group had the greatest LD values at all sites, while the IC group indicated the lowest LD values at all sites except the left anterior site. In terms of 3D distortions, the SB group had the largest RMS value, whereas the IC group showed the lowest RMS value. ∆X, ∆Y, and ∆Z values also showed significant differences at all sites (P<.001) except for the ∆Z values at the right anterior site (P=.194). The highest mean ∆X, ∆Y, and ∆Z values were recorded in the SB group except for the ∆Z measurement of the left posterior site.

CONCLUSIONS

The IC group outperformed the other groups. The AA group exhibited distortion comparable with that of the IC group. Splinting scan bodies or using scan aids enhanced the trueness.

摘要

问题陈述

关于夹板扫描体或使用三维(3D)打印扫描辅助设备对完整牙弓数字扫描的准确性的影响,研究较少。

目的

本体外研究的目的是比较在无牙颌上使用 6 种不同方法获得的多部位种植体记录的准确性。

材料和方法

将带有 4 个多单位模拟体的无牙颌的石膏模型从口外扫描,并将得到的数据保存为参考文件。为了获得实验文件,使用了 6 种不同的方法:带有开架式印模保持架的常规印模(IC)、不使用夹板扫描体或使用任何扫描辅助设备的口内扫描(IOS)(SB)、带有图案树脂夹板扫描体的 IOS(PR)、带有复合树脂夹板扫描体的 IOS(CR)、带有 3D 打印定制扫描体的 IOS(CSB)和带有 3D 打印辅助设备的 IOS(AA)。将实验文件在计量软件程序中与参考文件对齐。运行三维比较算法来量化均方根估计误差(RMS)。文件中的扫描体被转换为空心虚拟圆柱体,并记录穿过这些圆柱体中心的线的笛卡尔坐标,以分析角度(AD)和线性失真(LD)。进一步沿着 x(∆X)、y(∆Y)和 z 轴(∆Z)分析 LD。使用单向方差分析和 Tukey HSD 检验进行统计分析(α=.05)。

结果

所有部位的 AD、所有部位的 LD 和 RMS 误差均显示出显著差异(P<.05)。IC 组在所有部位的 AD 值最低,其次是 AA、CSB、PR、CR 和 SB 组。SB 组在所有部位的 LD 值最大,而 IC 组在所有部位的 LD 值最小,除了左前部位。在 3D 失真方面,SB 组的 RMS 值最大,而 IC 组的 RMS 值最小。除了右前部位的∆Z 值(P=.194)外,所有部位的∆X、∆Y 和∆Z 值也有显著差异(P<.001)。SB 组记录的∆X、∆Y 和∆Z 均值最高,除了左后部位的∆Z 测量值。

结论

IC 组的表现优于其他组。AA 组的失真与 IC 组相当。夹板扫描体或使用扫描辅助设备可提高准确性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验