Suppr超能文献

评估4D流磁共振成像在定量室间隔缺损小儿患者左向右分流中的应用:与右心导管检查的比较

Assessment of 4D flow MRI for quantification of left-to-right shunt in pediatric patients with ventricular septal defect: comparison with right heart catheterization.

作者信息

Zamani-Aliabadi Seyed Mohammad, Qanadli Salah D, Fatehi-Feyzabad Seyed Hasan, Ghasemnezhad Mohsen, Ghaemi Hamidreza, Azarine Arshid, Mohammadzadeh Ali, Bitarafan-Rajabi Ahmad, Mortezaeian Hojjat, Rezaei-Kalantari Kiara

机构信息

Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran.

Cardiothoracic and Vascular Division, Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.

出版信息

Front Cardiovasc Med. 2024 Jul 22;11:1399110. doi: 10.3389/fcvm.2024.1399110. eCollection 2024.

Abstract

OBJECTIVES

The percentage of shunt fraction significantly impacts the management of patients with congenital shunts, influencing strategic choices such as surgical or interventional procedures. This study compared the estimated shunt fraction (the ratio of pulmonary-to-systemic flow, Qp/Qs) for quantifying the left-to-right shunt in children with ventricular septal defect (VSD) using heart catheterization, four-dimensional (4D) flow, and two-dimensional (2D) flow magnetic resonance imaging (MRI). The goal was to establish a non-invasive and reliable measurement ratio between pulmonary and systemic blood flow in these patients.

METHODS

Between July 2022 and June 2023, patients scheduled to undergo invasive right heart catheterization were included in this study. MRI was performed one hour before the catheterization procedure. The correlation of shunt fraction was assessed between all methods after calculating the Qp/Qs ratio from 2D and 4D flow MRI and catheterization.

RESULTS

A total of 24 patients (aged 3-15 years, eight females) were ultimately included in the study. The Qp/Qs ratios obtained from 4D flow had a robust correlation (correlation coefficient r = 0.962) compared to those obtained during catheterization. Cardiac catheterization recorded the mean shunt fraction at 1.499 ± 0.396, while 4D flow measured it at 1.403 ± 0.344, with no significant difference between the two techniques. Moreover, there was a reasonable correlation (r = 0.894) between 2D flow measurements of Qp/Qs and the results obtained from catheterization, with a mean shunt fraction of 1.326 ± 0.283.

CONCLUSION

4D flow MRI has the potential to be a non-invasive method for accurately measuring the left-to-right shunt in children with VSD.

摘要

目的

分流分数的百分比对先天性分流患者的治疗管理有显著影响,会影响手术或介入治疗等策略选择。本研究比较了采用心导管检查、四维(4D)血流和二维(2D)血流磁共振成像(MRI)对室间隔缺损(VSD)患儿左向右分流进行量化时的估计分流分数(肺循环与体循环血流量之比,Qp/Qs)。目的是建立这些患者肺循环和体循环血流量之间的无创且可靠的测量比值。

方法

2022年7月至2023年6月期间,计划接受有创右心导管检查的患者纳入本研究。在导管检查前1小时进行MRI检查。在通过二维和四维血流MRI及导管检查计算出Qp/Qs比值后,评估所有方法之间分流分数的相关性。

结果

本研究最终纳入24例患者(年龄3至15岁,8例女性)。与导管检查获得的Qp/Qs比值相比,四维血流获得的Qp/Qs比值具有很强的相关性(相关系数r = 0.962)。心导管检查记录的平均分流分数为1.499±0.396,而四维血流测量值为1.403±0.344,两种技术之间无显著差异。此外,二维血流测量的Qp/Qs与导管检查结果之间存在合理的相关性(r = 0.894),平均分流分数为1.326±0.283。

结论

四维血流MRI有可能成为准确测量室间隔缺损患儿左向右分流的无创方法。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/4483/11298441/e3b56a30b417/fcvm-11-1399110-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验