Suppr超能文献

牙槽嵴放射影像评估校正系数的制定:一项初步研究。

Development of a correction coefficient for radiographic evaluation of the alveolar bone crest: a pilot study.

机构信息

Department of Oral Surgery and Orthopedics, Dental School, Federal University of Rio Grande do Sul (UFRGS), Porto Alegre, Rio Grande do Sul, Brazil.

出版信息

Clin Oral Investig. 2024 Aug 12;28(9):482. doi: 10.1007/s00784-024-05870-5.

Abstract

OBJECTIVES

To analyze the differences in cusp height on radiographs, establishing proportional relationships between cusp and alveolar bone crest (ABC) measurements. The goal of this study was to develop a correction coefficient by considering this proportion.

MATERIALS AND METHODS

Twenty-one artificial teeth, molars and premolars, and bovine ribs were used. Interproximal radiographs were taken with the aid of a positioner. The vertical angles used were: 0°, + 5°, and + 10°, and processed using three spatial resolutions measured in line pairs per mm (lp/mm): 20, 25 and 40. The Perio filter was applied to each image, in addition to the original one. Combinations of angle, resolution, and filter were made. Eighteen images were analyzed by three specialists, resulting in 252 measurements for each evaluator, totaling 756 measurements.

RESULTS

The overall variability of the measurements can be explained mainly by the variation in tooth anatomy. The 0° 25 lp/mm Perio filter method was the closest one to the actual clinical scenario for both cusps and ABC. The correction factor managed to explain 71.45% of the errors.

CONCLUSIONS

The variation in vertical angulation interferes with cusp and ABC measurements, and the angulation at 0º and spatial resolution of 25 lp/mm showed better results. The use of correction coefficients allowed approaching actual measurement values.

CLINICAL RELEVANCE

More accurate ABC height measurements are essential even in radiographic exams that do not meet the standard of excellence because the need to repeat radiographic exams is then eliminated.

摘要

目的

分析 X 光片上的牙尖高度差异,建立牙尖与牙槽嵴顶(ABC)测量之间的比例关系。本研究的目的是通过考虑这种比例来制定校正系数。

材料与方法

使用 21 个人工牙齿、磨牙和前磨牙以及牛肋骨。在定位器的帮助下拍摄邻间 X 光片。使用的垂直角度为:0°、+5°和+10°,并使用线对每毫米(lp/mm)测量的三种空间分辨率进行处理:20、25 和 40。对每张图像应用 Perio 滤波器,除了原始图像。组合角度、分辨率和滤波器。三位专家对 18 张图像进行了分析,每位评估员的测量结果为 252 次,总共有 756 次测量。

结果

测量的整体可变性主要可以用牙齿解剖结构的变化来解释。对于牙尖和 ABC,0°25 lp/mm Perio 滤波器方法最接近实际临床情况。校正因子成功地解释了 71.45%的误差。

结论

垂直角度的变化会干扰牙尖和 ABC 的测量,而 0°的角度和 25 lp/mm 的空间分辨率的结果更好。使用校正系数可以更接近实际的测量值。

临床相关性

即使在不符合卓越标准的 X 光检查中,ABC 高度的更准确测量也很重要,因为这可以避免重复 X 光检查的需要。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验