Ferreira Liana Matos, Queiroz Polyane Mazucatto, Santaella Gustavo Machado, Wenzel Ann, Groppo Francisco Carlos, Haiter-Neto Francisco
Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil.
Section of Oral Radiology, Department of Dentistry and Oral Health, University of Aarhus, Aarhus, Denmark.
Imaging Sci Dent. 2019 Jun;49(2):97-102. doi: 10.5624/isd.2019.49.2.97. Epub 2019 Jun 24.
This study was conducted to evaluate the effect of different spatial resolutions of a photostimulable phosphor plate (PSP) radiography system on the detection of proximal caries lesions.
Forty-five extracted human permanent teeth were radiographed using a PSP system (VistaScan Perio Plus) and scanned at the 4 resolutions (10 lp/mm, 20 lp/mm, 25 lp/mm, and 40 lp/mm) available in the system. Three independent examiners scored the images for the presence and absence of proximal caries lesions using a 5-point scale. The presence or absence of caries was confirmed by histological sections of the examined teeth (defined as the gold standard). Intra- and inter-observer reproducibility was calculated by the weighted kappa test. One-way analysis of variance with the post hoc Tukey test was used to compare the area under the receiver operating characteristic curve for the classifications made with each resolution.
For the detection of enamel lesions, the spatial resolution of 10 lp/mm was significantly superior to the other resolutions. However, the spatial resolution did not affect the detection of caries lesions in dentin (P>0.05).
Spatial resolution may influence the accuracy of the detection of incipient caries lesions in radiographs with PSP plates. Images with low spatial resolution seem to be more appropriate for this purpose.
本研究旨在评估光激励荧光板(PSP)射线照相系统的不同空间分辨率对近端龋损检测的影响。
使用PSP系统(VistaScan Perio Plus)对45颗拔除的人类恒牙进行射线照相,并以该系统可用的4种分辨率(10 lp/mm、20 lp/mm、25 lp/mm和40 lp/mm)进行扫描。三名独立的检查者使用5分制对图像上近端龋损的有无进行评分。通过检查牙齿的组织学切片(定义为金标准)来确认龋病的有无。观察者内和观察者间的再现性通过加权kappa检验计算。使用单因素方差分析和事后Tukey检验来比较每种分辨率下分类的受试者工作特征曲线下面积。
对于釉质病变的检测,10 lp/mm的空间分辨率显著优于其他分辨率。然而,空间分辨率对牙本质龋损的检测没有影响(P>0.05)。
空间分辨率可能会影响使用PSP板的射线照片中早期龋损检测的准确性。低空间分辨率的图像似乎更适合于此目的。