Department of Optometry, Ming Vision and Ophthalmology (J.Y., Y.Z.), Jianguomen Branch Clinic, Beijing, China; and Ineye Hospital of Chengdu University of TCM (Y.Z.), Chengdu, China.
Eye Contact Lens. 2024 Sep 1;50(9):375-383. doi: 10.1097/ICL.0000000000001104. Epub 2024 Aug 8.
The aim of this study was to analyze the effects of lens deviation on peripheral defocus and optic quality in adolescents with moderate and severe myopia.
This prospective study enrolled 81 children (81 eyes). The spherical equivalent was -5.0≤SE≤-6.0 diopter. The participants were divided into two subgroups based on their eccentricity (inferior temporal) after wearing the lenses for 12 months. Between them, the low eccentric subgroup (A) had a total eccentric distance of less than 0.5 mm, and the moderate and severe eccentric subgroup (B) had a total eccentric distance of ≥0.5 mm. Peripheral defocus and eccentricity were measured before and after wearing the lenses, and the Spearman test was used to compare the parameters.
Parameters such as the total peripheral defocus (TRDV) were significantly lower in subgroup B than in subgroup A after 12 months of orthokeratology lens usage. The axial length growth (ΔAL) in subgroup A was higher than that in subgroup B. Axial length growth, TRDV, and other parameters were significantly associated with eccentricity. The modulation transfer function cutoff and Strehl ratio were also significantly associated with eccentricity.
Greater eccentricity within a certain range can induce greater periretinal defocus and improve the ΔAL.
本研究旨在分析离焦对中、高度近视青少年周边离焦和像质的影响。
本前瞻性研究纳入 81 名儿童(81 只眼)。等效球镜度(SE)为-5.0≤SE≤-6.0 屈光度。根据戴镜 12 个月后的偏心距(下颞侧)将参与者分为两组。其中,低偏心亚组(A)的总偏心距离小于 0.5mm,中、高偏心亚组(B)的总偏心距离大于等于 0.5mm。测量戴镜前后的周边离焦和偏心度,采用 Spearman 检验比较参数。
戴角膜塑形镜 12 个月后,B 组的总周边离焦(TRDV)等参数明显低于 A 组。A 组的眼轴增长(ΔAL)高于 B 组。眼轴增长、TRDV 等参数与偏心距显著相关。调制传递函数截止值和斯特列尔比也与偏心距显著相关。
在一定范围内,更大的偏心度可以引起更大的周边离焦,从而提高ΔAL。