Suppr超能文献

角膜塑形术与离焦多焦点框架眼镜对近视控制效果的比较。

Comparison of myopic control between orthokeratology contact lenses and defocus incorporated multiple segments spectacle lenses.

机构信息

Institute of Medicine, Chung Shan Medical University, Taichung, Taiwan.

Nobel Eye Institute, Taipei, Taiwan.

出版信息

Int J Med Sci. 2024 May 19;21(7):1329-1336. doi: 10.7150/ijms.93643. eCollection 2024.

Abstract

The purpose of this study was to compare the differences in myopic control effects between orthokeratology (OK) contact lenses and defocus incorporated multiple segments (DIMS) spectacle lenses. A retrospective cohort study was conducted that included patients who had received OK lens, DIMS spectacle lens or single-vision spectacle treatments. A total of 54 eyes from 27 individuals, 38 eyes from 19 individuals and 42 eyes from 21 individuals were enrolled into the OK lens, DIMS and control groups, respectively. The primary outcomes were the changes in the spherical equivalent refraction (SER) and axial length (AXL) among the groups. A repeated-measure ANCOVA was adopted to calculate the SER progression and AXL elongation of the OK lens group compared with the DIMS group. The difference in the SER progression was clinically non-significant in the OK lens group compared with the DIMS and control groups (P = 0.001). The total AXL elongation results were similar between the OK lens and DIMS groups, but these were lower than in the control group (P = 0.005). The repeated-measure ANCOVA revealed that the SER progression difference during the study interval was clinically non-significant in the OK lens group when compared with the DIMS group (P = 0.028). The AXL elongation results between the OK lens and DIMS populations did not illustrate a significant difference (P = 0.607). In a subgroup analysis of moderate astigmatism, better AXL control was observed in the DIMS subgroup compared with the OK lens subgroup (P = 0.016). The OK lens demonstrated a clinically non-significant effect on the SER and AXL controls compared with the DIMS spectacle lens.

摘要

本研究旨在比较角膜塑形术(OK)角膜接触镜与离焦多焦点(DIMS)框架眼镜在近视控制效果方面的差异。这是一项回顾性队列研究,纳入了接受 OK 镜、DIMS 框架镜或单焦点框架镜治疗的患者。共有 27 名患者的 54 只眼、19 名患者的 38 只眼和 21 名患者的 42 只眼分别纳入 OK 镜组、DIMS 组和对照组。主要结局指标为各组间球镜等效屈光度(SER)和眼轴长度(AXL)的变化。采用重复测量方差分析(ANCOVA)比较 OK 镜组与 DIMS 组的 SER 进展和 AXL 伸长。与 DIMS 组和对照组相比,OK 镜组的 SER 进展差异在临床上无显著性意义(P = 0.001)。OK 镜组与 DIMS 组的总 AXL 伸长结果相似,但低于对照组(P = 0.005)。重复测量方差分析显示,在研究期间,OK 镜组与 DIMS 组之间的 SER 进展差异在临床上无显著性意义(P = 0.028)。OK 镜组和 DIMS 组的 AXL 伸长结果无显著差异(P = 0.607)。在中度散光的亚组分析中,与 OK 镜亚组相比,DIMS 亚组的 AXL 控制更好(P = 0.016)。与 DIMS 框架镜相比,OK 镜对 SER 和 AXL 的控制作用在临床上无显著差异。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/a61c/11134596/5ae0462cea1f/ijmsv21p1329g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验