A Novel Approach for Improving Gait Speed Estimation Using a Single Inertial Measurement Unit Embedded in a Smartphone: Validity and Reliability Study.

机构信息

Hinda and Arthur Marcus Institute for Aging Research, Hebrew SeniorLife, Boston, MA, United States.

Division of Gerontology, Beth Israel Deaconess Medical Center, Boston, MA, United States.

出版信息

JMIR Mhealth Uhealth. 2024 Aug 13;12:e52166. doi: 10.2196/52166.

Abstract

BACKGROUND

Gait speed is a valuable biomarker for mobility and overall health assessment. Existing methods to measure gait speed require expensive equipment or personnel assistance, limiting their use in unsupervised, daily-life conditions. The availability of smartphones equipped with a single inertial measurement unit (IMU) presents a viable and convenient method for measuring gait speed outside of laboratory and clinical settings. Previous works have used the inverted pendulum model to estimate gait speed using a non-smartphone-based IMU attached to the trunk. However, it is unclear whether and how this approach can estimate gait speed using the IMU embedded in a smartphone while being carried in a pants pocket during walking, especially under various walking conditions.

OBJECTIVE

This study aimed to validate and test the reliability of a smartphone IMU-based gait speed measurement placed in the user's front pants pocket in both healthy young and older adults while walking quietly (ie, normal walking) and walking while conducting a cognitive task (ie, dual-task walking).

METHODS

A custom-developed smartphone application (app) was used to record gait data from 12 young adults and 12 older adults during normal and dual-task walking. The validity and reliability of gait speed and step length estimations from the smartphone were compared with the gold standard GAITRite mat. A coefficient-based adjustment based upon a coefficient relative to the original estimation of step length was applied to improve the accuracy of gait speed estimation. The magnitude of error (ie, bias and limits of agreement) between the gait data from the smartphone and the GAITRite mat was calculated for each stride. The Passing-Bablok orthogonal regression model was used to provide agreement (ie, slopes and intercepts) between the smartphone and the GAITRite mat.

RESULTS

The gait speed measured by the smartphone was valid when compared to the GAITRite mat. The original limits of agreement were 0.50 m/s (an ideal value of 0 m/s), and the orthogonal regression analysis indicated a slope of 1.68 (an ideal value of 1) and an intercept of -0.70 (an ideal value of 0). After adjustment, the accuracy of the smartphone-derived gait speed estimation improved, with limits of agreement reduced to 0.34 m/s. The adjusted slope improved to 1.00, with an intercept of 0.03. The test-retest reliability of smartphone-derived gait speed was good to excellent within supervised laboratory settings and unsupervised home conditions. The adjustment coefficients were applicable to a wide range of step lengths and gait speeds.

CONCLUSIONS

The inverted pendulum approach is a valid and reliable method for estimating gait speed from a smartphone IMU placed in the pockets of younger and older adults. Adjusting step length by a coefficient derived from the original estimation of step length successfully removed bias and improved the accuracy of gait speed estimation. This novel method has potential applications in various settings and populations, though fine-tuning may be necessary for specific data sets.

摘要

背景

步速是评估移动能力和整体健康状况的一个有价值的生物标志物。现有的测量步速的方法需要昂贵的设备或人员协助,限制了它们在无人监督的日常生活条件下的使用。配备单个惯性测量单元(IMU)的智能手机的可用性为在实验室和临床环境之外测量步速提供了一种可行且方便的方法。先前的工作已经使用倒立摆模型来使用附着在躯干上的非智能手机的基于 IMU 来估计步速。然而,目前尚不清楚这种方法是否以及如何在智能手机的 IMU 嵌入在裤兜中并在行走时携带的情况下估计步速,尤其是在各种行走条件下。

目的

本研究旨在验证和测试在健康的年轻和老年成年人行走时(即正常行走)和进行认知任务时(即双重任务行走)将智能手机 IMU 放置在用户前裤兜中进行基于智能手机的步速测量的可靠性。

方法

使用定制的智能手机应用程序(app)记录 12 名年轻成年人和 12 名老年成年人在正常和双重任务行走期间的步态数据。将智能手机的步速和步长估计值的有效性和可靠性与 GAITRite 垫的金标准进行了比较。应用基于相对于原始步长估计的系数的基于系数的调整来提高步速估计的准确性。对于每个步幅,计算了智能手机和 GAITRite 垫之间步态数据的误差幅度(即偏差和协议范围)。使用 Passing-Bablok 正交回归模型提供智能手机和 GAITRite 垫之间的一致性(即斜率和截距)。

结果

与 GAITRite 垫相比,智能手机测量的步速是有效的。原始协议范围为 0.50 m/s(理想值为 0 m/s),正交回归分析表明斜率为 1.68(理想值为 1),截距为-0.70(理想值为 0)。调整后,智能手机衍生的步速估计精度得到了提高,协议范围缩小到 0.34 m/s。调整后的斜率提高到 1.00,截距为 0.03。在监督的实验室环境和无人监督的家庭环境中,智能手机衍生的步速测试-再测试可靠性良好至优秀。调整系数适用于广泛的步长和步速范围。

结论

使用智能手机的惯性测量单元(IMU)放置在年轻人和老年人的口袋中,可以通过倒立摆方法来估计步速,这是一种有效的可靠方法。通过从原始步长估计中导出的系数来调整步长,可以成功消除偏差并提高步速估计的准确性。这种新方法在各种环境和人群中具有潜在的应用,但可能需要针对特定数据集进行微调。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/722c/11336779/227e3144d531/mhealth-v12-e52166-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验