Abstract

BACKGROUND

Photon-counting computed tomography (PCCT) enables new ways of image reconstruction, e.g. material decomposition and creation of virtual non-contrast (VNC) series with higher resolution and lower radiation dose than standard computed tomography (CT). Clinical experiences of this are limited.

PURPOSE

To compare true non-contrast (TNC) series with VNC series derived from non-enhanced (VNC), arterial phase (VNC) and portal venous phase (VNC) in clinically approved PCCT.

MATERIAL AND METHODS

A total of 45 clinical, tri-phasic abdominal CT scans from the PCCT Naetom Alpha, between February 2022 and November 2022, were retrospectively assessed. Placing a region of interest in six different locations in each VNC series - right liver parenchyma, left liver parenchyma, spleen, aorta, erector spinae muscle, and in the subcutaneous fat - absolute Hounsfield values (HU) and standard deviations (SD) were collected. Differences in HU (ΔHU) were compared and statistically analyzed.

RESULTS

Statistically significant differences between VNC and TNC were seen in all measurements, with the largest difference in the subcutaneous fat and the smallest difference in the erector spinae muscle. Only small differences were seen between VNC and VNC, where the largest differences were seen in the left and right liver lobes.

CONCLUSION

VNC images from the first-generation clinically approved PCCT showed a significant difference between VNC and TNC images. The differences vary with the type of tissue. Only small differences were seen depending from which contrast phase the VNC was derived.

摘要

背景

光子计数计算机断层扫描(PCCT)能够实现新的图像重建方式,例如物质分解和创建比标准计算机断层扫描(CT)分辨率更高、辐射剂量更低的虚拟非对比(VNC)系列。目前临床应用经验有限。

目的

在临床批准的 PCCT 中,比较真实非对比(TNC)系列与源自非增强(VNC)、动脉期(VNC)和门静脉期(VNC)的 VNC 系列。

材料与方法

回顾性分析 2022 年 2 月至 2022 年 11 月期间在 PCCT Naetom Alpha 上进行的 45 例临床三相位腹部 CT 扫描。在每个 VNC 系列的六个不同位置(右肝实质、左肝实质、脾脏、主动脉、竖脊肌和皮下脂肪)放置一个感兴趣区,收集绝对亨氏单位(HU)和标准偏差(SD)的绝对值。比较 HU 差异(ΔHU)并进行统计学分析。

结果

所有测量值均显示 VNC 与 TNC 之间存在统计学显著差异,皮下脂肪差异最大,竖脊肌差异最小。VNC 与 VNC 之间仅存在较小差异,左、右肝叶差异最大。

结论

第一代临床批准的 PCCT 的 VNC 图像与 TNC 图像之间存在显著差异。差异随组织类型而变化。仅根据 VNC 的对比期来源观察到较小的差异。