Suppr超能文献

与钛椎弓根螺钉相关的CT上金属伪影的量化

Quantification of metallic artifact on CT associated with titanium pedicle screws.

作者信息

Lewis M J, Early P J, Bergman R, Love K, Nelson N

机构信息

Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, Raleigh, NC, United States.

Synapse Veterinary Services, Fort Mill, SC, United States.

出版信息

Front Vet Sci. 2024 Jul 31;11:1448188. doi: 10.3389/fvets.2024.1448188. eCollection 2024.

Abstract

BACKGROUND

In dogs undergoing vertebral column stabilization, post-operative computed tomography (CT) evaluates implant placement. The impact on the interpretation of metallic artifact associated with titanium implants in dogs remains to be established. Our objective was to quantify metallic artifact on CT associated with titanium pedicle screws.

METHODS

The study design included an model and a retrospective review of 11 dogs with vertebral column stabilization. Twenty four titanium pedicle screws (6 each: 2.0 mm, 2.7 mm, 3.5 mm, and 4.5 mm) were inserted into a 20% ballistic gel, and CT scan of the construct was performed. Three blinded raters used a bone window to measure the maximum width (effective size) of each screw, one rater measured effective size using an ultrawide window and 45 titanium pedicle screws (3×2.0 mm, 5×2.7 mm, 30×3.5 mm, and 7×4.5 mm) in 11 clinical cases. Effective size measurements were compared to actual screw sizes.

RESULTS

The effective size was 26.9-43.8%, 9.2-18.5%, and 21.1-30.5% larger than the actual size for the system (bone window), system (ultrawide window), and clinical cases, respectively. The mean gross difference for the measurements varied by implant size ( < 0.001) and was positively correlated with implant size ( = 0.846), but the mean percentage difference was negatively correlated with implant size ( < 0.001). Overestimation was larger for the model bone window compared to the ultrawide window ( < 0.001) and clinical cases ( = 0.001).

CONCLUSION

Metallic artifact associated with titanium pedicle screws on CT resulted in an overestimation of screw size. This information might aid in the interpretation of implant placement on post-operative imaging.

摘要

背景

在接受脊柱稳定手术的犬类中,术后计算机断层扫描(CT)用于评估植入物的放置情况。钛植入物在犬类中所产生的金属伪影对图像解读的影响尚待明确。我们的目的是量化与钛椎弓根螺钉相关的CT金属伪影。

方法

研究设计包括一个模型以及对11只接受脊柱稳定手术的犬类进行回顾性分析。将24枚钛椎弓根螺钉(每种规格6枚:2.0毫米、2.7毫米、3.5毫米和4.5毫米)插入20%的弹道凝胶中,并对该结构进行CT扫描。三名不知情的评估者使用骨窗测量每枚螺钉的最大宽度(有效尺寸),一名评估者使用超宽窗测量有效尺寸,以及对11例临床病例中的45枚钛椎弓根螺钉(3×2.0毫米、5×2.7毫米、30×3.5毫米和7×4.5毫米)进行测量。将有效尺寸测量结果与实际螺钉尺寸进行比较。

结果

对于模型(骨窗)、模型(超宽窗)和临床病例,有效尺寸分别比实际尺寸大26.9 - 43.8%、9.2 - 18.5%和21.1 - 30.5%。模型测量的平均总差异因植入物尺寸而异(P < 0.001),且与植入物尺寸呈正相关(r = 0.846),但平均百分比差异与植入物尺寸呈负相关(P < 0.001)。与超宽窗(P < 0.001)和临床病例(P = 0.001)相比,模型骨窗的高估情况更严重。

结论

CT上与钛椎弓根螺钉相关的金属伪影导致螺钉尺寸被高估。该信息可能有助于解读术后影像上的植入物放置情况。