Suppr超能文献

通过设置排气孔改良两步印模法:技术报告

Modified Two-Step Impressions via the Incorporation of Venting Holes: A Technical Report.

作者信息

Alqutaibi Ahmed Yaseen, Hamadallah Hatem Hazzaa, Rahhal Mohamed M, Ibrahim Wafaa Ibrahim

机构信息

Substitutive Dental Sciences (Prosthodontics), College of Dentistry, Taibah University, Al-Madinah Al-Munawwarah, SAU.

Prosthodontics, College of Dentistry, Ibb University, Ibb, YEM.

出版信息

Cureus. 2024 Jul 16;16(7):e64642. doi: 10.7759/cureus.64642. eCollection 2024 Jul.

Abstract

This study presents a methodology for obtaining a precise impression of the crown margin of prepared teeth by utilizing a two-step impression technique. The method begins with the fabrication of a custom tray made from heat-cured acrylic resin, followed by the acquisition of an initial impression using putty elastomeric material. Subsequently, the impression is relieved around the prepared teeth, and vent holes are strategically placed through both the impression and the tray. Finally, a light-body consistency impression material is applied. This streamlined technique enhances efficiency and minimizes the errors commonly encountered with traditional two-step impression methods.

摘要

本研究提出了一种通过使用两步印模技术来获得预备牙齿牙冠边缘精确印模的方法。该方法首先制作由热固化丙烯酸树脂制成的定制托盘,然后使用糊剂型弹性材料获取初始印模。随后,在预备牙齿周围对印模进行减压,并在印模和托盘上策略性地设置排气孔。最后,应用轻体稠度的印模材料。这种简化的技术提高了效率,并将传统两步印模方法中常见的误差降至最低。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/6989/11325460/ece2a074170b/cureus-0016-00000064642-i01.jpg

相似文献

1
Modified Two-Step Impressions via the Incorporation of Venting Holes: A Technical Report.
Cureus. 2024 Jul 16;16(7):e64642. doi: 10.7759/cureus.64642. eCollection 2024 Jul.
5
[ evaluation of the application of digital individual tooth tray in the impression making of mandibular full-arch crown abutments].
Beijing Da Xue Xue Bao Yi Xue Ban. 2020 Dec 18;53(1):54-61. doi: 10.19723/j.issn.1671-167X.2021.01.009.
7
A clinical pilot study of the dimensional accuracy of double-arch and complete-arch impressions.
J Prosthet Dent. 2002 May;87(5):510-5. doi: 10.1067/mpr.2002.124489.
9
Linear dimensional accuracy of a polyvinyl siloxane of varying viscosities using different impression techniques.
J Investig Clin Dent. 2010 Aug;1(1):37-46. doi: 10.1111/j.2041-1626.2010.00004.x. Epub 2010 Jul 9.
10
The effect of tray selection on the accuracy of elastomeric impression materials.
J Prosthet Dent. 1990 Jan;63(1):12-5. doi: 10.1016/0022-3913(90)90257-d.

本文引用的文献

1
Evaluation of One- and Two-Step Impression Techniques and Vertical Marginal Misfit in Fixed Prothesis.
Int J Dent. 2023 Feb 21;2023:9898446. doi: 10.1155/2023/9898446. eCollection 2023.
2
Accuracy of Single-Step versus 2-Step Double-Mix Impression Technique.
ISRN Dent. 2011;2011:341546. doi: 10.5402/2011/341546. Epub 2011 Jul 25.
4
Polyvinyl siloxane impression materials: an update on clinical use.
Aust Dent J. 1998 Dec;43(6):428-34. doi: 10.1111/j.1834-7819.1998.tb00204.x.
5
A laboratory study of dimensional changes for three elastomeric impression materials using custom and stock trays.
Aust Dent J. 1996 Dec;41(6):398-404. doi: 10.1111/j.1834-7819.1996.tb06026.x.
6
7
Accuracy of one-step versus two-step putty wash addition silicone impression technique.
J Prosthet Dent. 1992 May;67(5):583-9. doi: 10.1016/0022-3913(92)90151-y.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验